Method 2: Hardware
When set with jumpers, the Activator ID is a binary number
represented by jumpers. A
1 is represented by a jumper on the
header and a
0 is represented by an absence of a jumper (Table 2).
Once an Activator ID is set by jumpers, it can
not be reset with serial
commands. In order for serial commands to take effect, the jumpers
must be removed, the unit must powered down and then rebooted.
However, even with the jumpers removed the Activator will maintain
the ID that had been set with jumpers until reprogrammed with the
serial command.
NOTE
Before the Activator ID is set with jumpers, the default ID is 127,
although there are no jumpers on the headers.
ID#
Jumpers
JP19 JP12
ID#
Jumpers
JP19 JP12
3
0 0 0 0 0 0 1 1
70
0 1 0 0 0 1 1 0
13
0 0 0 0 1 1 0 1
72
0 1 0 0 1 0 0 0
14
0 0 0 0 1 1 1 0
75
0 1 0 0 1 0 1 1
21
0 0 0 1 0 1 0 1
80
0 1 0 1 0 0 0 0
22
0 0 0 1 0 1 1 0
83
0 1 0 1 0 0 1 1
24
0 0 0 1 1 0 0 0
93
0 1 0 1 1 1 0 1
27
0 0 0 1 1 0 1 1
94
0 1 0 1 1 1 1 0
33
0 0 1 0 0 0 0 1
100
0 1 1 0 0 1 0 0
34
0 0 1 0 0 0 1 0
103
0 1 1 0 0 1 1 1
44
0 0 1 0 1 1 0 0
105
0 1 1 0 1 0 0 1
47
0 0 1 0 1 1 1 1
106
0 1 1 0 1 0 1 0
52
0 0 1 1 0 1 0 0
113
0 1 1 1 0 0 0 1
55
0 0 1 1 0 1 1 1
114
0 1 1 1 0 0 1 0
57
0 0 1 1 1 0 1 0
124
0 1 1 1 1 1 0 0
58
0 1 0 0 0 1 0 1
127
0 1 1 1 1 1 1 1
69
0 1 0 0 0 1 1 0
Table 2 Activator IDs and their jumper positions
To set the Activator ID with jumpers
1: Power down the Activator and disconnect the wake-up antenna.