PROBLEM

POSSIBLE CAUSE AND SOLUTION

Tilter raises very slowly.

Check for pinched tubing or hose. Where pipe is

used, check for obstruction in the line.

The oil is extremely viscous due to low ambient

temperatures. Add or replace with lower weight oil
that stays thinner in cold conditions (5W-15, etc.)

The motor voltage or wiring may be incorrect.

Check for a line or hose leak.

Check for oil shortage in the reservoir. Add oil as

necessary (See Oil Requirements in the “Routine
Maintenance” section.)

The pump may be seized if motor is humming or

blowing fuses on overload protection devices.
Remove the pump. The pump should be able to be
rotated by hand. Check for cracks in the housing.

The battery may not be charged. Charge battery.

The air pressure is too low.