ACF-10 Series

Rev. 1a, 2/03

Automation Products Group, Inc.

APG...Providing tailored solutions for measurement applications

Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]

8

• Adjustment

1. DETECT Switch

For shifting the magnetizing state of the
output relay. The magnetizing state of the
output relay is as follows:

At Non-Detection

At Detection

Detect On

OFF

ON

Non Detect

ON

OFF

2. OFFSET Adjusting Trimmer

An offset adjusting trimmer for noise
component
left ... larger right ... smaller

3. GAIN Adjustment Trimmer

An adjusting trimmer for amplifying only
input signals
left ... smaller right ... larger

4. ON DELAY Adjusting Trimmer

A time adjusting trimmer for ON DELAY
Max. setting time is approx. 7 seconds

5. OFF DELAY Adjusting Trimmer

A time adjusting trimmer for OFF
DELAY. Max. setting time is approx. 7
seconds

6. LED Display

The red LED (4 pieces) indicate the
intensity of input signals. When the LED
illuminate, the relay will be switched on.

1

6

5

4

3

2

NON

DETECT

ZERO

RY ON

DELAY

DELAY

GAIN

OFFSET

OFF

ON

DETECT