STOP TRANSMIT SENSOR
Stop Transmit Sensor allows the user to identify a sensor and have it start
transmitting. This command controls a single sensor.
To have sensor number 1 stop transmitting, use the command structure;
Send
AAh
Start Byte
01h,
Sensor Number
21h
Command
01h
NA
00h
NA
55h
End Byte
START TRANSMIT BANK
Start Transmit Bank allows the user to identify a bank of sensors and have
them start transmitting. This command controls up to 10 sensors providing they
are all assigned to the same bank.
To have Bank number 1 begin transmitting, use the command structure;
Send
AAh
Start Byte
00h,
NA
22h
Command
01h
Bank Number)
00h
NA
55h
End Byte
STOP TRANSMIT BANK
Stop Transmit Bank (e) allows the user to identify a bank of sensors and have
them stop transmitting. This command controls up to 10 sensors providing they
are all assigned to the same bank.
To have Bank number 1 stop transmitting, use the command structure;
Send
AAh
Start Byte
00h,
NA
23h
Command
01h
Bank Number
00h
NA
55h
End Byte