APG IRU-3000 user manual User Manual
Page 16

IRU-2xx4/3xx4
Rev. A2, 11/08
16
Automation Products Group, Inc.
APG...Providing tailored solutions for measurement applications
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]
AVERAGE
Average: The sensor will average the number of samples set in the Average
Parameter. Each qualified sample is placed into a buffer and averaged with the
previous samples to generate a steady output. A qualified sample is one that falls
within the boundaries set in the Out of Range Span Parameter.
To Read the number of samples being averaged in a sensor, use the command
structure:
Send
Receive
AAh
Start Byte
66h
Start Byte
01h,
Sensor Number
01h
Sensor Number
0Fh
Command
0Fh
Command
00h
Data (not used)
##h
Average (High Byte)
00h
Data (not used)
##h
NA (Low Byte)
55h
End Byte
##h
NA
99h
Stop Byte
To change the average to 7 in the sensor, use the command structure;
Send
AAh
Start Byte
01h,
Sensor Number
10h
Command
07h
Data
Number of samples to average
00h
Data (not used)
55h
End Byte