• Maintenance

When cleaning and checking the container, free the paddle and shaft from

deposit. The unit which detects the level of sticky materials or is installed in a
humid location must be cleaned at periodic intervals.

Tighten the housing cover and cable entry to protect the unit from rain,

splashing water, etc.

• Make sure that the power supply is turned off .
• Remove the housing cover (by turning it counterclockwise).
• Remove lead wires by melting the soldered area with a soldering iron.
• Remove the micro switch (loosen one screw).
• Install the replacement switch and tighten the screw.
• Re-solder lead wires. Refer to fi gure below.
• Check wiring and operation.
• Reinstall and tighten the housing cover.