beautypg.com

Warning, Important – Echo 74500 Owners Manual v.4 User Manual

Page 13

background image

5" and 8" Skid Steer Chipper Owner's Manual

11

OPERATION

Figure 4.3 - Installed Couplers

the skid steer chipper is equipped to attach to flush face

couplers (Figure 4.3). the chipper is shipped with -12 sized

hydraulic couplers fitted on the hoses. a tie wrap is used to

indicate the pressure line. Be sure to connect the hydraulic

hoses to the proper ports.
if the skid steer is fitted with anything other than -12 sized

flush face couplers on the main lines, it will be necessary

to replace the couplers supplied with the chipper.
the chippers are also equipped with a case drain hose. the

case drain is used to eliminate pressure on the chipper’s

hydraulic motor. the motor is rated for 250 to 300 psi of

back pressure.
Most high flow skid steer loaders are equipped with a case drain

line. Standard flow skid steer loaders typically are not.

if the

back pressure is over 300 psi, a case drain line will have

to be added. contact your skid steer dealer for details.

To connecT:

Before connecting, make sure to relieve the hydraulic

pressure in the skid steer using the skid steer system.
remove dirt and debris from the surface of the couplers.
visually check the couplers for damage; replace if

damage is found.
install the male coupler into the female coupler. Full

connection is made when the ball release sleeve slides

forward on the female coupler.
turn the sleeve so that it is rotated away from the lock-

ing pin to prevent accidental disconnection.
repeat the procedure for all hoses, including the

smaller case drain hose.

To disconnecT:

relieve the hydraulic pressure in the skid steer using

the skid steer system.
rotate the ball sleeve so the grooves are aligned with

the pins in the female coupler.
retract the sleeve on the female coupler until the

couplers disconnect.
repeat the procedure for all hoses.

1.

2.
3.

4.

5.

6.

1.

2.

3.

4.

Hydraulic lines may be under pressure due to testing

done at the factory.

4.3 insTall flush face couPlers

Warning

NOt addiNg a CaSe draiN liNe vOidS tHe

CHiPPer WarraNty!