8 replacing hydraulic drive belt, 9 fill coolant (diesel), 10 change oil – Echo CH611DH Owners Manual v.3 User Manual
Page 23: English
19
6 INCH CHIPPER
ENGLISH
SERVICE & MAINTENANCE
BEFORE INSPECTINg OR SERVICINg ANy PART OF THIS MACHINE, SHuT OFF POWER SOuRCE,
DISENgAgE THE HyDRAulICS, AND MAKE SuRE All MOVINg PARTS HAVE COME TO A COMPlETE STOP.
WaRNING
5.8 REpLaCING HYDRauLIC DRIvE bELT
Remove drive belt according to instructions in Section
1.
5.5.
loosen the two bolts under the pump. Access is from
2.
underneath chipper (see figure below).
Slide the pump up, remove the loosened hydraulic
3.
belt and discard.
Install the new hydraulic belt.
4.
Replace the drive belt according to directions in Section
5.
5.5.
Tighten the nuts on the adjusting bolt to move the pump
6.
mounting bracket. Stop when the belt deflection at the
center of the belt is 7/16" when a 20 lb. load is placed
against the belt (see figure below).
tighten the mounting bolts on the pump mounting
7.
bracket to the proper torque.
LOOSEN THESE
TWO BOLTS
HYDRAULIC
DRIVE BELT
IDLER PULLEY
HYDRAULIC
BELT PULLEY
Replace hydraulic drive belt as needed
The condition of the hydraulic drive belt should be checked
annually, or after every 25 hours of operation. Replace
the belt if it is cracked, worn, frayed, or stretched.
to replace the belt:
Proper belt tension is a deflection of 7/16" for a 20 lb. load
SPAN LENGTH
FORCE
20 LBS
7/16" DEFLECTION
5.9 FILL CooLaNT (DIESEL)
Coolant tank for diesel engine
The diesel engine is tested before shipping. In order to test
the equipment the fluid levels are filled. However, before
starting the machine, and every time the engine is started
thereafter, be sure to check the coolant level. If the level
is low, add fluid.
Refer to the engine owner’s manual for coolant information
and maintenance.
5.10 CHaNGE oIL
Check the oil level before each use. Change oil as directed
in the engine owner's manual.
The controller will blink a code every 100 hours as a
reminder to change oil. To reset the controller, see Sec.
7.4.