beautypg.com

6 chipper feed controller, 7 feed roller control bar – Echo CH611DH Owners Manual v.3 User Manual

Page 18

background image

14

6 INCH CHIPPER

OPERATION

4.6 CHIppER FEED CoNTRoLLER

NoTE

The RPM sensor on the rotor must be flashing or the

controller won’t work. Clearance between the sensor

and the bolt must be between 1/32” and 3/32”. There

are also two sensors in the feed roller control box.

These sensors must have a clearance of 5/64"(2mm).

4.7 FEED RoLLER CoNTRoL baR

Feed Roller Control bar is used to manually control the

direction of the feed roller rotation.

Move the feed roller bar to FORWARD (F) when you

want the materials to feed into the chipper.
Move the feed roller bar to REVERSE (R) when you

want the chipper push materials back out of the feed

chute (when materials become jammed).
Move the feed roller bar to STOP to halt the rotation

of the feed roller.

RESET/OVERRIDE

BUTTON (WHERE

AVAILABLE)

CONTROLLER LIGHT

FEED ROLLER

CONTROL BAR

SAFETY BAR

(WHERE

AVAILABLE)

R

R

F

S

EuRopEaN moDELS oNLY
push the Safety bar in the event of an emergency
and

forward feed will stop. Push the reset/override button to

resume forward feed.
upon start-up, the controller light will glow a steady red.

Push the reset/override button to reset.
If false trips occur, the rest button can be held in for 5

seconds to override the system.

This machine is equipped with a Plus 1 Controller. The

controller monitors the rotor RPM and regulates the feed

roller.
When chipper Rpm drops too low, the feed roller is

stopped automatically to help the chipper process

backed up materials.

When Rpm is back up to an acceptable level, the feed

roller will automatically reengage.

When the hydraulic pressure is too high, (if the feed

roller becomes obstructed) the controller will reverse

the feed roller momentarily to try to remove the material

that wasn’t chipped. The controller will then engage

the roller into the forward position and try to feed the

material again.

If this cycle continues, the obstruction will have to be

removed manually, or materials should be removed,

trimmed, and/or repositioned.

The controller light will flash the following codes (See

Sec. 7.4 for more information):

Normal operating RPM:

Steady green light.

feed bar Not in Stop:

flashing red light indicates

feed bar must be in Stop position upon startup.

15 hour Service Code

: flashing amber light is a

reminder to check blade sharpness.

100 hour Service Code

: flashing amber light is a

reminder to change oil.

RPM too Low

: flashing green light.

Safety Bar Activated:

Steady red light (European

models only).

The controller comes preprogrammed at the factory. If it

should malfunction, contact your dealer. The controller

will not allow the chipper to operate until it has been

properly programmed.

This manual is related to the following products: