beautypg.com

9 lofa control programming, English – Echo CH911DH Owners Manual v.2 User Manual

Page 21

background image

9 INCH CHIPPER

17

ENGLISH

SERVICE & MAINTENANCE

BEFORE INSPECTINg OR SERVICINg ANy PART OF THIS MACHINE, SHuT OFF POWER SOuRCE,

AND MAkE SuRE All MOVINg PARTS HAVE COME TO A COMPlETE STOP.

WARNING

5.9 LoFA CoNTRoL PRoGRAmmING

NoTE

When approaching the end of a log, it may be necessary

to manually override the automatic feed sensor. Be sure

to pay attention to the engine speed and feeding of the

material.

To program the sensor, see below.

STEP 1. INITIATING PRoGRAm moDE

Hold down the “S” button while turning the engine key

to the “on” position until “l” starts to flash on the lCD

(Figure 5.6).

STEP 2. ENTER LoW (L = LoW) RPm

The low setting is the RPM speed where the feed roller

stops. The “up” arrow increases the RPM setting, while

the “down” arrow decreases the RPM setting. Setting the

speed lower causes the engine to lug down more before

the feed roller stops.

Hold the appropriate (either up or down) arrow until

1.

the desired RPM speed is displayed (Recommended

1375 rpm).
Push the “S” button once with the desired RPM setting

2.

displayed to save. Do not choose a setting equal to or

below zero.

STEP 3. ENTER NoRmAL (N = NoRmAL) RPm

The normal setting is the RPM speed that the chipper rotor

usually rotates

Hold the appropriate (either up or down) arrow until

1.

the desired RPM speed is displayed (Recommended

1500 rpm).
Push the “S” button once with the desired RPM setting

2.

displayed to save.

STEP 4. ENTER HIGH (H = HIGH) RPm

The high setting is not needed with this application.

Set to zero to deactivate.

1.

Push the “S” button once with zero displayed to save.

2.

STEP 5. ENTER RETuRN (RET = RETuRN) RPm

The return setting is the RPM speed where the feed roller

restarts. The feed roller should restart before the rotor

reaches “normal” RPM to maximize chipper efficiency.

Setting the speed higher allows the engine to recover more

before the feed roller restarts.

Hold the appropriate (either up or down) arrow until

1.

the desired RPM speed is displayed (Recommended

1400 rpm).

Figure 5.6, LOFA control

STEP 6. ENTER NumbER oF PoLES

(IPu=NumbER

oF PoLES)

The number of poles is used to indicate the number of

speed pickup devices.

Hold the appropriate (either up or down) arrow until

1.

(1) is displayed.
Push the "S" button once with one (1) displayed to

2.

save.

This manual is related to the following products: