Deutz engine dipstick -11 – JLG 600A_AJ Service Manual User Manual
Page 27

SECTION 1 - SPECIFICATIONS
3121201
– JLG Lift –
1-11
10. Oil Change w/Filter - Deutz
Lube Point(s) - Fill Cap/Spin-on Element
Capacity - 11 Quarts Crankcase; 5 Quarts Cooler
Lube - EO
Interval - Every Year or 1200 hours of operation
Comments - Check oil level, fill oil to max marking
on the dipstick. Check level daily/Change in accor-
dance with engine manual. Refer to Figure 1-3.,
Deutz Engine Dipstick.
11. Oil Change w/Filter - Caterpillar
Lube Point(s) - Fill Cap/Spin-on Element
Capacity - 10.6 Quarts
Lube - EO
Interval - 3 Months or 150 hours of operation
Comments - Check level daily/Change in accor-
dance with engine manual.
12. Oil Change w/Filter - GM
Lube Point(s) - Fill Cap/Spin-on Element
(JLG P/N 7027965)
Capacity - 4.5 qt. (4.25 L) w/filter
Lube - EO
Interval - 3 Months or 150 hours of operation
Comments - Check level daily/Change in accor-
dance with engine manual.
13. Fuel Filter - Ford
Lube Point(s) - Replaceable Element
Interval - Every Year or 1200 hours of operation
MINIMUM LEVEL,
OIL HOT
MINIMUM OIL
LEVEL
MINIMUM LEVEL,
OIL COLD
NOTE: Hot oil checks should not be made until the engine
has been shut down for a period of 5 minutes.
MAXIMUM LEVEL,
OIL HOT
MAXIMUM LEVEL,
OIL COLD
MAXIMUM OIL
LEVEL
Figure 1-3. Deutz Engine Dipstick