12 operator maintenance and lubrication, Operator maintenance and lubrication -5, Operator maintenance and lubrication diagram -5 – JLG 600SC_660SJC Service Manual User Manual
Page 23: Lubrication specifications -5
SECTION 1 - SPECIFICATIONS
3121157
– JLG Lift –
1-5
1.12 OPERATOR MAINTENANCE AND
LUBRICATION
NOTE: The following numbers correspond to those in Figure
1-2., Operator Maintenance and Lubrication Dia-
gram.
LUBRICATION INTERVALS ARE BASED ON MACHINE OPERATION
UNDER NORMAL CONDITIONS. FOR MACHINES USED IN MULTI-
SHIFT OPERATIONS AND/OR EXPOSED TO HOSTILE ENVIRON-
MENTS OR CONDITIONS, LUBRICATION FREQUENCIES MUST BE
INCREASED ACCORDINGLY.
1.
Swing Bearing
Lube Point(s) - 2 Grease Fittings
Capacity - A/R
Lube - MPG
Interval - Every 3 months or 150 hrs of operation
Comments - Remote Access
Figure 1-2. Operator Maintenance and Lubrication Diagram
Table 1-18. Lubrication Specifications
KEY
SPECIFICATIONS
MPG
Multipurpose Grease having a minimum dripping point of 350° F
(177° C). Excellent water resistance and adhesive qualities, and
being of extreme pressure type.
(Timken OK 40 pounds minimum.)
EPGL Extreme Pressure Gear Lube (oil) meeting API service
classification GL-5 or MIL-Spec MIL-L-2105
HO
Hydraulic Oil. API service classification GL-3, e.g. Mobilfluid
424.
EO
Engine (crankcase) Oil. Gas - API SF, SH, SG class, MIL-L-
2104. Diesel - API CC/CD class, MIL-L-2104B/MIL-L-2104C.