SPECIFICATIONS Continued

* If wire is applied at ambient greater than 30

°

C (86

°

F), consult Table 310-16 of the NEC (ANSI/NFPA 70). If other than uncoated (non-plated), 60

°

or 75

°

C

(140

°

or 167

°

F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the

NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60

°

C (140

°

F) conductors, per the NEC

(ANSI/NFPA 70) Article 336-30.

† The factory refrigerant charge is for 15 ft of interconnecting tubing. For tubing lengths other than 15 ft, see Long-Line Application Guideline for additional

refrigerant requirements.

‡ Time-delay fuse or HACR breaker.

** Length shown is as measured 1 way along the wire path between the unit and the service panel for voltage drop not to exceed 2%.

†† For indicator light function, thermostat specified must be used and wired according to efficiency service alarm Installation Instructions.
‡‡ Used with low-ambient controller.

*** Fan motor with ball bearings required.

††† High-pressure switch must be added if not supplied with the system.
‡‡‡ Outdoor thermostat required.
N/A—Not Applicable

UNIT SIZE-SERIES

048-A

060-A

Operating Weight (Lb)

265

327

ELECTRICAL

Unit Volts-Hertz-Phase

208/230-60-1

Operating Voltage Range

187—253

Unit Ampacity for Wire Sizing

34.0

45.0

Min Wire Size (60

°

C/75

°

C Copper) (AWG)*

8/10

6/8

Maximum Length (60

°

C/75

°

C) (Ft)**

91/56

116/66

Max. Branch Circuit Fuse Size (Amps)‡

50

60

Compressor Rated Load Amps

26.5

34.9

Locked Rotor Amps

129.0

169.0

Fan Motor HP and RPM

1/8 and 820

1/5 and 820

Full Load Amps

1.0

1.4

COMPRESSOR AND REFRIGERANT

Compressor

Scroll

Refrigerant—Type and Amount (Lb)†

R-22 and 11.88

R-22 and 14.88

OUTDOOR COIL AND FAN

Coil Face Area (Sq Ft)

18.18

24.89

Rated Airflow (CFM)

2900

3600

OPTIONAL EQUIPMENT

Support Feet—4 In. (4)

KSASF0101AAA

Snow Stand—18 In.

KHASS0206MPK

KHASS0306MPK

Time-Delay Relay

KAATD0101TDR

Interface Control‡‡‡

KHAIC0101AAA

Service Alarm

KHASA0101AAA††

Outdoor Thermostat

KHAOT0301FST

Secondary Outdoor Thermostat

KHAOT0201SEC

Cycle Protector

Standard

Crankcase Heater

Standard

Start Assist—PTC

KAACS0201PTC

Start Capacitor and Relay

KSAHS1601AAA

Sound Hood

Standard

Bi-flow TXV Kits (Hard Shutoff)

KHATX1301HSO

KHATX1401HSO

Bi-flow TXV Kits (RPB)

N/A

Low-Pressure Switch

Standard

High-Pressure Switch

Standard

Evaporator Freeze Thermostat

KAAFT0101AAA‡‡

Isolation Relay

KHAIR0101AAA‡‡

Liquid Solenoid Valve (LSV)

KHALS0101LLS

Filter Drier—Bi-flow

P504-8163S (RCD)

Low-Ambient Controller

P251-0083 (RCD)

MotorMaster® Control

32LT660004***

Ball Bearing Fan Motor

HC38GE230 (RCD)

Thermostat, Auto Changeover,
Non-Programmable,

°

F/

°

C,

2-Stage Heat, 1-Stage Cool

TSTATBHNHP01-A

Thermostat, Auto Changeover,
7-Day Programmable,

°

F/

°

C,

2-Stage Heat, 1-Stage Cool

TSTATBHPHP01-A

Thermostat, Manual Changeover,
Non-Programmable,

°

F,

2-Stage Heat, 1-Stage Cool

HH07AT214

Thermostat, Auto Changeover,
Non-Programmable,

°

F/

°

C,

Dual Fuel Thermostat. Must be used with
Outdoor Sensor (TSTATBBSEN01)

TSTATBHPDF01-A†††

Outdoor Sensor

TSTATBBSEN01