20— detailed cooling capacities* continued – Bryant SPLIT-SYSTEM 697C User Manual
Page 20
—20—
DETAILED COOLING CAPACITIES* Continued
See notes on page 26.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES
°
F
85
95
105
115
CFM
EWB
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Total
Sens‡
Total
Sens‡
Total
Sens‡
Total
Sens‡
697C030-B Outdoor Section With FC4BNF036 Indoor Section Continued
850
72
32.1
16.0
2.43
30.7
15.5
2.65
29.3
14.9
2.89
27.8
14.4
3.16
67
29.3
20.3
2.41
28.0
19.8
2.62
26.8
19.3
2.86
25.5
18.8
3.13
63††
27.3
19.7
2.39
26.1
19.2
2.60
24.8
18.7
2.84
23.4
18.1
3.10
62
26.8
24.5
2.38
25.8
24.0
2.60
24.5
23.4
2.84
23.2
22.7
3.10
57
26.0
26.0
2.38
25.1
25.1
2.59
24.2
24.2
2.83
23.1
23.1
3.10
950
72
32.4
16.5
2.47
31.0
16.0
2.69
29.6
15.5
2.94
28.0
15.0
3.20
67
29.8
21.4
2.45
28.4
20.8
2.67
27.1
20.3
2.91
25.6
19.7
3.17
63††
27.7
20.7
2.43
26.4
20.2
2.65
25.2
19.7
2.89
23.8
19.1
3.15
62
27.3
25.9
2.43
26.2
25.3
2.64
25.1
24.7
2.89
23.8
23.8
3.15
57
26.8
26.8
2.43
25.9
25.9
2.64
24.9
24.9
2.89
23.8
23.8
3.15
1050
72
32.9
17.2
2.52
31.5
16.7
2.74
30.0
16.1
2.98
28.1
15.5
3.25
67
30.0
22.4
2.49
28.7
21.8
2.71
27.4
21.3
2.95
25.9
20.7
3.22
63††
27.9
21.6
2.48
26.6
21.1
2.69
25.4
20.6
2.93
24.1
20.0
3.20
62
27.8
27.2
2.48
26.6
26.4
2.69
25.5
25.5
2.93
24.4
24.4
3.20
57
27.5
27.5
2.47
26.6
26.6
2.69
25.6
25.6
2.94
24.4
24.4
3.20
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Cooling
Indoor
Section
Size
Cooling
Capacity
Power
Capacity
Power
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CK3BA
030
1.01
0.93
CC5A/CD5A/CD5BA
036
1.02
0.94
036
1.02
0.93
CD5A/CD5BW
036
1.02
0.94
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CD3(A,B)A
036
1.02
0.94
CJ5A/CK5A/CK5BW
036
1.02
0.93
CJ5A/CK5A/CK5BW
030
1.01
0.93
CK3BA
030
1.01
0.94
036
1.02
0.93
036
1.02
0.93