JLG 660SJ Service Manual User Manual
Page 265
SECTION 6 - JLG CONTROL SYSTEM
3121202
– JLG Lift –
6-19
BASKET ROTATE
ACCELeration
0.1 to 5.0
1.8
DECELeration
0.1 to 3.0
0.7
MlNimum LEFT speed
0 to 65%
46
MAXimum LEFT speed
0 to 100%
50
MINimum RIGHT speed
0 to 65%
46
MAXimum RIGHT speed
0 to 100%
50
Engine RPM
800 to 2900
1500
JIB LIFT
ACCELeration
0.1 to 5.0
5.0
DECELeration
0.1 to 3.0
1.0
MINimum UP speed
0 to 65%
46
MAXimum UP speed
0 to 100%
52
MINimum DOWN speed
0 to 65%
45
MAXimum DOWN speed
0 to 100%
52
Engine RPM
800 to 2900
1800
STEER
MAXimum speed
0 to 100%
100
Engine RPM
800 to 2900
1800
GROUND MODE
Tower LIFT UP speed
0 to 100%
N/A
Tower LIFT DOWN speed
0 to 100%
N/A
Upper LIFT UP
0 to 100%
60
Upper LIFT DOWN
0 to 100%
60
SWING speed
0 to 100%
60
Upper TELEscope speed
0 to 100%
70
Tower TELEscope speed
0 to 100%
N/A
BASKET ROTATE speed
0 to 100%
50
BASKET LEVEL speed
0 to 100%
50
JIB LIFT speed
0 to 100%
50
NOTE:
Personality settings can be adjusted anywhere within the adjustment range in order to achieve optimum machine performance.
4150365-5
Table 6-1. Personality Ranges/Defaults
FUNCTION
PERSONALITY
RANGE
DEFAULTS - 600S