8 machine personality settings, Machine personality settings -17, Personality ranges/defaults -17 – JLG 660SJ Service Manual User Manual
Page 263
SECTION 6 - JLG CONTROL SYSTEM
3121202
– JLG Lift –
6-17
6.8 MACHINE PERSONALITY SETTINGS
NOTE: Personality settings can be adjusted within the
adjustment range in order to achieve optimum
machine performance.
Table 6-1. Personality Ranges/Defaults
FUNCTION
PERSONALITY
RANGE
DEFAULTS - 600S
DRIVE
ACCELeration
0.1s to 5.0s
2.0
DECELeration
0.1s to 3.0s
2.0
Forward MINimum speed
0 to 35%
4
Forward MAXimum speed
0 to 100%
35
REVerse MINimum speed
0 to 35%
4
REVerse MAXimum speed
0 to 100%
35
ELEVATED MAXimum speed
0 to 50%
15
CREEP MAXimum speed
0 to 50%
25
Engine RPM
800 to 2900
1800
TOWER LIFT
ACCELeration
0.1 to 5.0
N/A
DECELeration
0.1 to 3.0
N/A
MlNimum UP speed
0 to 60%
N/A
MAXimum UP speed
0 to 100%
N/A
MINimum DOWN speed
0 to 60%
N/A
MAXimum DOWN speed
0 to 100%
N/A
Engine RPM
800 to 2900
N/A
UPPER LIFT
ACCELeration
0.1 to 5.0
2.0
DECELeration
0.1 to 3.0
0.7
MlNimum UP speed
0 to 60%
40
MAXimum UP speed
0 to 100%
80
CREEP Maximum UP speed
0 to 65%
55
MINimum DOWN speed
0 to 60%
40
MAXimum DOWN speed
0 to 100%
70
CREEP maximum DOWN speed
0 to 75%
55
Engine RPM
800 to 2900
1800