SECTION 5 - HYDRAULICS
5-18
– JLG Lift –
3121202
5.5 VARIABLE DISPLACEMENT PUMP (M46
SERIES)
Troubleshooting
GAUGE INSTALLATION
It will be necessary to install a high pressure gauge into
the system pressure gauge ports to check the setting of
the high pressure relief valves.
Measuring the charge pump inlet vacuum will help locate
restrictions in the inlet lines, filter, etc.
Case pressure readings can help locate restrictions in the
return lines, oil cooler, and return filter.
Gauge Information
M1
System Pressure
Port A
10, 000 PSI or 600 Bar Gauge
9/16-18 O-ring Fitting
M2
System Pressure
Port B
10, 000 PSI or 600 Bar Gauge
9/16-18 O-ring Fitting
M3
Charge Pressure
1000 PSI or 60 Bar Gauge
9/16-18 O-ring Fitting or Tee into
Charge Pressure Filter Outlet Line
L1
L2
Case Pressure
1000 PSI or 60 Bar Gauge
1-1/16-12 O-ring Fitting
S
Charge Pump Inlet
Vacuum
Vacuum Gauge
Tee into Charge Pump Inlet Line
M4
Servo Pressure
1000 PSI or 60 Bar Gauge
9/16-18 O-ring Fitting
M5
Servo Pressure
1000 PSI or 60 Bar Gauge
9/16-18 O-ring Fitting