19 limit switch adjustment, Elevation switch, 20 door adjustment – JLG 3246E2 ANSI Service Manual User Manual
Page 49: Limit switch adjustment -35, Quick welder™ installation -35
![background image](/manuals/551701/49/background.png)
SECTION 2 - PROCEDURES
3120737
– JLG Lift –
2-35
2.19 LIMIT SWITCH ADJUSTMENT
Elevation Switch
On the 1532E2/1932E2/3246E2 there is a platform limit
switch located at the head of the lift cylinder on the middle
inside arm. When activated, the switch cuts out the Drive
function if the Pothole Protection is not set. The cut out
heights are set at a maximum of the following:
2.20 DOOR ADJUSTMENT
NOTE: There is an eccentric bolt on the hinge side under-
neath of each door. If the door needs raised or low-
ered this can be accomplished by turning these
bolts. Adjust these bolts to the outside to avoid drag
on the pothole protection system when the door is
opened.
NOTE: There are two bolts on top of each door in the cor-
ners. These are designed to take the weight off the
pothole protection system and distribute it around
the underside of the frame if the machine were to be
run over any uneven terrain or dropped into any
void. The clearance between the top of the bolts and
the frame should be a min. of 3/4 in to a max. of 1 1/
2 in.
WELDER
TERMINAL
CONNECTOR
FIRE
EXTINGUISHER
Figure 2-11. Quick Welder
™
Installation
Model
In
m
1532E2
84
2.1
1932E2
104
2.6
3246E2
112
2.8