JLG 18RS Service Manual User Manual
Page 18

SECTION 1 - SPECIFICATIONS
1-6
– JLG Lift –
3121284
2. Swing Bearing/Worm Gear Teeth
Lube Point(s) - Grease Fitting
Capacity - A/R
Lube - Lubriplate 930-AAA
Interval - A/R
Lube Point(s) - Grease Fitting*
Capacity - A/R
Lube - Mobile SHC 007
Interval - A/R
DO NOT OVERGREASE BEARINGS. OVERGREASING BEARINGS
WILL RESULT IN DAMAGE TO OUTER SEAL IN HOUSING.
*If necessary install grease fitting into worm gear
housing and grease. Replace fitting with pipe plug
when complete.
3. Hydraulic Tank
Lube Point(s) - Fill Cap
Capacity - 36 Gal. (136.3 L), 32.5 Gal. (123 L) to Full
Level; 26.5 Gal (100.3 L) to Refill Mark
Lube - HO
Interval - Check Level daily; Change every 2 years or
1200 hours of operation.
Comments - On new machines, those recently over-
hauled, or after changing hydraulic oil, operate all
systems a minimum of two complete cycles and
recheck oil level in reservoir.
4. Hydraulic Tank Return Filter and Breather
Interval - Change after first 50 hrs. and every 6
months or 300 hrs. thereafter.
Comments - For breather element, remove wing nut
and cover to replace. Under certain conditions, it
may be necessary to replace both elements on a
more frequent basis.