Table 6-4. Fault Code List
DTC
Text
001
EVERYTHING OK
0010
RUNNING AT CUTBACK - OUT OF TRANSPORT POSITION
0011
FSW OPEN
0012
RUNNING AT CREEP - CREEP SWITCH OPEN
0013
RUNNING AT CREEP - TILTED AND ABOVE ELEVATION
0014
CHASSIS TILT SENSOR OUT OF RANGE
0030
RUNNING AT CREEP - PLATFORM STOWED
0031
FUEL LEVEL LOW - ENGINE SHUTDOWN
211
POWER CYCLE
212
KEYSWITCH FAULTY
213
FSW FAULTY
224
FUNCTION PROBLEM - STEER LEFT PERMANENTLY SELECTED
225
FUNCTION PROBLEM - STEER RIGHT PERMANENTLY SELECTED
227
STEER SWITCHES FAULTY
2211
FSW INTERLOCK TRIPPED
2212
DRIVE LOCKED - JOYSTICK MOVED BEFORE FOOTSWITCH
2213
STEER LOCKED - SELECTED BEFORE FOOTSWITCH
2216
D/S JOY. OUT OF RANGE HIGH
2217
D/S JOY. CENTER TAP BAD
2219
L/S JOY. OUT OF RANGE HIGH
2220
L/S JOY. CENTER TAP BAD
2221
LIFT/SWING LOCKED - JOYSTICK MOVED BEFORE FOOTSWITCH
2222
WAITING FOR FSW TO BE OPEN
2223
FUNCTION SWITCHES LOCKED - SELECTED BEFORE ENABLE
2224
FOOTSWITCH SELECTED BEFORE START
2247
FUNCTION PROBLEM - PLATFORM ROTATE LEFT PERMANENTLY SELECTED
2248
FUNCTION PROBLEM - PLATFORM ROTATE RIGHT PERMANENTLY SELECTED
2249
FUNCTION PROBLEM - JIB LIFT UP PERMANENTLY SELECTED
2250
FUNCTION PROBLEM - JIB LIFT DOWN PERMANENTLY SELECTED
2251
FUNCTION PROBLEM - TELESCOPE IN PERMANENTLY SELECTED
2252
FUNCTION PROBLEM - TELESCOPE OUT PERMANENTLY SELECTED
2257
FUNCTION PROBLEM - TOWER LIFT UP PERMANENTLY SELECTED
2258
FUNCTION PROBLEM - TOWER LIFT DOWN PERMANENTLY SELECTED
2262
FUNCTION PROBLEM - PLATFORM LEVEL UP PERMANENTLY SELECTED
2263
FUNCTION PROBLEM - PLATFORM LEVEL DOWN PERMANENTLY SELECTED
234
FUNCTION SWITCHES FAULTY - CHECK DIAGNOSTICS/BOOM
235
FUNCTION SWITCHES LOCKED - SELECTED BEFORE AUX POWER
236
FUNCTION SWITCHES LOCKED - SELECTED BEFORE START SWITCH
237
START SWITCH LOCKED - SELECTED BEFORE KEYSWITCH
2310
FUNCTION PROBLEM - GROUND ENABLE PERMANENTLY SELECTED
2370
FUNCTION PROBLEM - JIB LIFT UP PERMANENTLY SELECTED