beautypg.com

Installation, Accessibility – Aerovent IM-631 User Manual

Page 3

background image

Aerovent IM-631

3

Installation

Models BSD53 and BSB53 are all designed to be lifted

onto the building by using the windband brackets which

double as lifting points for these models. Units can be

lifted onto the building with or without the windband

mounted onto the unit. Straps or chain capable of

handling the load of the unit should be securely

attached to each of the four windband brackets.

The

unit should not be lifted by any other parts such as drive

frame, motor, damper blades, windband, orifice panel,

curb cap, etc.

Once the fan has been carefully lifted onto the roof

curb, it should be secured by installing fasteners into all

of the holes provided in the base of the fan.

WARNING: Units with the fusible link assembly are

under extremely high spring tension. Care must be

taken to not accidentally set off the damper lifters when

servicing the fan. The fusible link damper lifters are

located under the butterfly damper blades. Failure to

exercise caution could cause severe injury or death.

Accessibility

Motor and drive assemblies on models BSB53 and

BSD53 can be accessed from the roof by removing

the stack cap and orifice panel assemblies from the

roof curb. A hinged base is available as an accessory

on sizes 36 and below to allow for easier access from

the roof.

Note: Aerovent recommends the use of an inlet safety

guard on all non-ducted installations.

Windband

Brackets

Removable

Motor Cover

Removable

Access Panel