beautypg.com

Snorkel TB126J CE User Manual

Page 62

background image

Chapter 11 – Troubleshooting

58

TB126J – 0192117EE

Symptom

Possible Cause

Corrective Action

Engine will not start from upper

controls.

Switches are set wrong. The engine

will not crank.

Turn the battery disconnect switch

on and then at the lower controls:

Turn the control selector switch

off.
Pull the emergency stop button

outward.
Place the controls selector in

the lower control position.
Wait for 5 seconds and then turn

the switch to start.

From the upper controls:

Turn the master start switch

off.
Pull the emergency stop button

outward.
Place the master start switch

in the on position for 5 seconds

and the then turn the switch to

start.

Platform foot switch is activated.

Do not step on foot switch while

starting the engine.

The master start switch was left in

the on position for 30 seconds or

longer before turning it to start.

Turn the master start switch back

to off, then to start within 30 sec-

onds.

The main system circuit breaker

on the upper control panel or the

wiring box has tripped. The engine

will not crank.

Push the main system circuit break-

er button back in. If the button pops

back out, refer the problem to a

qualified service technician.

Engine starts from the upper con-

trols but no boom functions work

– machines with AC generator op-

tion only.

The machine/generator switch is in

the generator position.

Place the switch in the machine

position to operate machine func-

tions.

Engine dies when the control selec-

tor switch at the lower controls is

placed in the platform position.

Upper controls are not set-up prop-

erly.

At the upper controls, pull the emer-

gency stop button upward and turn

the anti-restart master switch on.

Light in emergency stop button

is illuminated while the engine is

running.

High engine temperature.

Lower the platform and reduce the

engine speed to idle for five min-

utes. Turn the engine off and let it

cool. Do not restart the engine until

the cause of overheating has been

corrected.

Low oil pressure.

Lower the platform and turn the

engine off. Do not restart the engine

until the cause of low oil pressure

has been corrected.

No alternator current/broken fan

belt.

Turn the engine off. Do not restart

the engine until the cause of no al-

ternator current has been corrected

or the fan belt is replaced.