12. OPTIONS
12 - 1
P/N 0191482
AC GENERATOR
C A U TIO N
Do not use the AC GENERATOR unless the
hydraulic oil is over 70°F (21°C). The output
voltage of the generator depends on the
temperature of the hydraulic oil. Temperature
below 70°F (21°C) will cause dangerously low
output voltages that can burn out some kinds of
electrical equipment.
The hydraulically powered, 120 V ac generator
can be used anytime the TB 120 engine is
running and the TB 120 is completely stationary.
Turning the generator on stops all machine
movement.
Set the MACHINE/GENERATOR switch (1) to
GENERATOR and a total of 2 kW, continuous
duty, 120 V ac power is available from the two
electrical outlets (2) under the platform-control
box or the electrical outlet on the end of the
generator housing.
NOTE: To energize the two platform electrical
outlets, the power cord (3) from the platform
outlets must be plugged into the receptacle on
the generator (4).
AIR LINE TO PLATFORM
The input to the air line is on the bottom left-rear
of the turntable.
The outlet is on the platform mounting frame.
The maximum safe
working pressure for the
air line is 250 psi (1725 kPa).
12. OPTIONS