Ems table – Snorkel TB120 2000 User Manual
Page 17
2. SAFETY DEVICES
2 - 3
P/N 0191482
EMS TABLE
LIGHT
CONDITION
AUDIO ALARM
EMS
STATUS
ON: Machine is ready for normal operation.
FLASHING: Calibration error. Notify qualified service
technician. DO NOT USE MACHINE.
None.
None.
EMS
ENVELOPE
OFF: Platform is well inside the working envelope.
FLASHING: Platform is less than 3 feet (1 m) inside the
working envelope.
ON: Platform is at the limits of the working envelope.
None.
None.
None.
EMS
WARNING
ON: EMS error detected. Press the red EMS WARNING
light completely in and release it
slowly. If the red EMS
WARNING light stays on, use the emergency
procedures described in the “EMERGENCY
OPERATION” chapter to lower the platform.
FLASHING: Platform is outside the limits of the working
envelope. Move boom into working envelope.
Continuous tone.
Beeping
EXTENDIBLE-AXLE INTERLOCKS
The left and right rear axles of a TB 120 must
be extended and locked for safe-working
machine stability. The booms cannot be raised
or extended unless the axles are completely
extended and locked into place. Instructions for
extending and locking the axles are given in the
“OPERATION” chapter.
FLASHING LIGHTS (option)
The flashing lights alert people that the TB 120
is present. The lights flash at about one flash
per second anytime the engine is running.
There is no ON/OFF switch for the flashing
lights.
GREEN
WHITE
RED