Chapter 9. operation, Preparing for operation 9-1, Lower controls 9-1 – Snorkel S2033 User Manual
Page 36: Upper controls 9-1, Preparing for operation, 9-1, 9-2, Danger
Chapter 9. Operation
The aerial platform may be operated from either
the lower or upper controls.
The aerial platform is not electrically
insulated. Death or serious injury can result
from contact with, or inadequate clearance
from, an energized conductor. Do not go
closer than the minimum safe approach
distance as defined by ANSI.
Pinch points may exist between moving
components. Death or serious injury can
result from becoming trapped between
components, buildings, structures, or other
obstacles. Make sure there is sufficient
clearance around the machine before moving
the chassis or platform. Allow sufficient room
and time to stop movement to avoid contact
with structures or other hazards.
The aerial platform can tip over if it becomes
unstable. Death or serious injury can result
from a tip-over accident. Operate the aerial
platform on a firm, flat, level surface. Avoid
travel speeds and/or rough terrain that could
cause sudden changes in platform position.
The operator bears ultimate responsibility for
ensuring that the aerial platform is properly set
up for the particular conditions encountered.
■
Preparing for Operation
Make certain the batteries are charged and the
charger is unplugged before operating the aerial
platform. Use the following procedure to prepare
the aerial platform for operation.
1. Close and latch the swing-out battery and
hydraulic component trays.
2. From the lower controls, place the battery
disconnect switch in the on position (refer to
Figure 9.1).
Figure 9.1—Lower Controls
3. Lift the emergency stop guard and push the
toggle switch up.
4. Place the control selector switch in the lower
position.
5. Operate the platform raise/lower switch to
make sure the aerial platform is functioning
properly.
■
Lower Controls
The lower controls override the upper controls.
This means that the lower controls can always be
used to operate the platform regardless of the
position of the upper controls emergency stop
switch.
The lower controls may be used for initial set up
of the aerial platform and raising and lowering the
platform while testing or inspection.
The lower controls (refer to Figure 9.1) are
located on the right side of the chassis. The
following are located at the lower control station.
●
Battery disconnect switch
●
Emergency stop switch
●
Control selector switch
●
Platform raise/lower switch
●
Circuit breaker reset button
●
Low voltage warning light
■
Upper Controls
The upper controls may be used for positioning
the aerial platform and raising and lowering the
platform while on the job.
The upper controls (refer to Figure 9.2) are
located on the right side of the platform. The
following are located at the upper control station.
●
Emergency stop button
●
Drive/lift selector switch
●
Low voltage warning light
●
Joystick to control platform lift, drive, and
steer
The optional horn button and battery condition
indicator gauge may also be located at the upper
control station.
S2033 – 0390076
page 9 - 1
DANGER
Battery
Disconnect
Switch
Control Selector
Switch
Platform
Raise/Lower
Switch
Emergency
Stop Switch