Chapter 11 – Troubleshooting

62

AB80J/AB85J – 0420453EE

Symptom

Engine will not start from

lower controls.

Engine will not start from

upper controls.

Continued on next page...

Possible Cause

Switches are set wrong. The engine

will not crank.

The master start switch was left in

the on position for 30 seconds or

longer before turning it to start.

The main system circuit breaker on

the lower control panel has tripped.

The engine will not crank.

Switches are set wrong. The engine

will not crank.

Platform foot switch is activated.

The master start switch was left in

the on position for 30 seconds or

longer before turning it to start.

Corrective Action

Turn the battery disconnect switch on

and then at the lower controls:

• Turn the master start switch off.

• Pull emergency stop button out-

ward.

• Place the controls switch in the

lower control position.

• Place the master start switch in

the on position for 5 seconds and

then turn the switch to start.

Turn the start switch back to off, then

to start within 30 seconds.

Push the main system circuit breaker

button back in. If the button pops back

out, refer the problem to a qualified

service technician.

Turn the battery disconnect switch on

and then at the lower controls:

• Turn the master start switch off.

• Pull the emergency stop button

outward.

• Place the controls switch in the

upper control position.

• Place the master start switch in

the on position.

From the upper controls:

• Turn the master start switch off.

• Pull the emergency stop button

outward.

• Place the master start switch in

the on position for 5 seconds and

the then turn the switch to start.

Do not step on foot switch while start-

ing the engine.

Turn the master start switch back to

off, then to start within 30 seconds.