Chapter 7 – Prestart Inspection

AB80J/AB85J – 0420453EE

33

Lower Control Station

With no personnel in the platform, test the operation

of each control from the lower controls (refer to Figure

7.2).

Figure 7.12 – Lower Controls

Operating Controls

Use the following procedure to operate the machine from

the lower controls.

. Turn the battery disconnect switch on.

2. At the lower controls, pull the emergency stop button

outward. Insert the key in the control selector switch

and turn the switch to the lower control position.

3. Press the start button until the engine starts, then

release.

Note

If the machine has a GM engine, there will be a 7 to 10

second delay after starting the engine, before the throttle

will go to mid or high. Start the engine and wait 10 seconds

before proceeding with machine operation.

4. Let the engine warm to operating temperature.

5. Hold the ground operation switch upward.

A

Danger

Pinch points may exist between moving components.

Death or serious injury can result from becoming

trapped between components, buildings, structures,

or other obstacles. Make sure all personnel stand

clear of the aerial platform while performing the pre-

start inspection.

A

Warning

The potential for an accident increases when operat-

ing an aerial platform that is damaged or malfunc-

tioning. Death or serious injury can result from such

accidents. Do not operate the aerial platform if it is

damaged or malfunctioning.

6. Test the operation of each function in both direc-

tions.

Note

When checking the turntable rotation function in the clock-

wise direction, the turntable will rotate toward you.

Emergency Stop

Push the emergency stop button inward to turn off the

engine. The lower control functions should not operate

with the emergency stop in this position.

Emergency Power

Place the battery disconnect switch, the emergency stop

switch, and the start switch in the on position.

Hold the engine/emergency power switch down and the

ground operation switch upward to operate the aerial

platform from the lower controls using the emergency

power system.

Manual Emergency Lowering Pump

The riser and main booms can be lowered in an emer-

gency using the emergency lowering pump. The emer-

gency lowering pump is behind the cowling door on the

left side of the machine.

Use the following procedure to test the emergency lower-

ing system.

. Use the lower controls to raise the riser and main

booms a few feet.

2. Turn the engine off.

A

Danger

Pinch points may exist between moving components.

Death or serious injury can result from becoming

trapped between components. Stand clear of moving

components while test operating the machine.

3. The pump handle is mounted next to the Operator’s

Manual holder. Insert the handle into the pump (refer

to Figure 7.3).

Start Button

Engine/Emergency Power Switch

Control

Selector

Switch

Emergency Stop Button

Ground

Operation

Switch