beautypg.com

Chapter 3 – safety, Danger, Electrocution hazards – Snorkel AB85RJ User Manual

Page 13: Minimum safe approach distance

background image

AB85RJ – 0421533

9

Chapter 3 – Safety

Knowledge of the information in this manual, and proper
training, provide a basis for safely operating the aerial plat-
form. Know the location of all controls and how they oper-
ate to act quickly and responsibly in an emergency.

Safety devices reduce the likelihood of an accident. Never
disable, modify, or ignore any safety device. Safety alerts
in this manual indicate situations where accidents may
occur.

If any malfunction, hazard or potentially unsafe condi-
tion relating to capacity, intended use, or safe operation
is suspected, stop aerial platform operation and seek
assistance.

The operator bears ultimate responsibility for following
all manufacturer’s instructions and warnings, regulations
and safety rules of their employer and/or any state or
federal law.

Electrocution Hazards

The aerial platform is made of metal components and is
not insulated. Regard all conductors as energized. Do
not operate outside during a thunderstorm.

Minimum Safe Approach Distance

Minimum safe approach distances to energized power
lines and their associated parts must be observed while
operating the aerial platform.

A

Danger

The aerial platform is not electrically insulated. Death
or serious injury can result from contact with, or
inadequate clearance from, an energized conductor.
Do not go closer than the minimum safe approach
distance as defined by ANSI or national safety regu-
lations.

ANSI publications define minimum distances that must
be observed when working near bus bars and energized
power lines. Table 1 and Figure 3 are reprinted courtesy
of Scaffold Industry Association, ANSI/SIA A92.5.

Table 1 – Minimum Safe Approach Distance

Figure 3 – Minimum Safe Approach Distance

Minimum Safe Approach Distance

Voltage Range

(Phase to Phase)

0 to 300V

Over 300V to 50kV

Over 50kV to 200kV

Over 200kV to 350kV

Over 350kV to 500kV

Over 500kV to 750kV

Over 750kV to 1000kV

Feet

Meters

Avoid Contact

10

15

25

20

35

45

3.05

4.60

6.10

7.62

10.67

13.72