Fault
Check
Cause
Solution
Fluid coming out of
hydraulic
À uid tank
Connected unit
not in rest position
yet and
À uid
coming out of
¿ ller
cap?
Return of the hydraulic
À uid from the rescue
device exceeds the
reservoir’s maximum
quantity when
¿ lled.
Reduce
À uid level in
the hydraulic tank to
“Minimum” mark, move
the unit to the rest
position and then
¿ ll
back up with hydraulic
À uid to the “Maximum”
level
Fluid leaks from a
different location?
Leak from tank, lines or
seals
Replace defective
components or repair
by authorised dealer or
Lukas directly
Leaking
À uid
between engine and
À ange bearing
Radial shaft seal on the
drive shaft is defective
Have it repaired by
authorised dealer or
directly by LUKAS
Hydraulic
À uid milky
and cloudy
Water / condensation in
the system
Replace the hydraulic
À uid immediately
Hoses cannot be
coupled
Pressure too high (e.g.
caused by ambient
temperature too high)
Switch valve block to
circulation at static
pressure
Coupling defective
Coupling must be
replaced immediately