Help Menu

The Help Menu provides users information on where to get additional help.

5.16

Self Diagnosis

Self diagnosis runs basic tests indicating any faults with the unit. There are three ways to

initiate the test: a Go To preset 86 command; the last option under MIC Setups on the On-

Screen Menu; and the camera can self-start the test on boot if the user loops the telemetry to

itself (TxA to RxA, and TxB and RxB). On a system where there may be a communication issue,

the last option is likely to be the best. This should be checked directly at the PSU first and

then in the control room, as there may be a fault in the setup between the two not allowing

the MIC to talk to itself.

Running a Self Diagnosis Test

The MIC 500 Series Camera moves to a specified test position, then checks for valid resolver

readings and reliable camera module communications. Then, the camera tests the pan and tilt

drives and camera zoom. Finally, it activates the wiper (seen from the pole base or on the

video). The results of each test are displayed as they are completed. If all of the tests pass,

but the camera still does not work properly, there may be a problem elsewhere in the system.

If any faults are detected, call the manufacturer for assistance.

Tour (Step : Preset : Dwell)

1 : 1 : Default

2 : 2 : Default

3 : 3 : Default

4 : 4 : Default

5 : 5 : Default

Sony Set Table 1 Mapped To

Normal

Sony Set Table 1

Auto Focus, Auto White Balance,

Auto Exposure, Effect Off

Sony Set Table 2 - 10 Mapped To Nothing

Sectors

Cleared

Setting

Default Value

MAIN MENU

2/2 a

..HELP..

SONY SET
CAPTIONS

WEBSITE
WWW.BOSCHSECURITY.COM

POT TEST

SUPPORT

MIC INFORMATION

USA

1 888 289 0096

SET USER ACCESS

EMEA

131 40 2577 284

HELP

ASIA

65 6319 3450

EXIT