MIC Series 500 Camera

Navigating the Menus | en

35

Bosch Security Systems, Inc.

User’s Manual

F.01U.173.601 | 2.0 | 2010.11

5.8.1

Alarm Relays and Re-arm Time

The multi alarm card also provides 2 output relays which the camera activates under certain

programmable circumstances. The options are as follows:

For example, if alarm input 4 triggers the PSU, it can be configured to close relay 1 and open

relay 2, or open relay 1 and do nothing with relay 2, etc. This is a way of providing the alarm

information to other equipment or resetting the alarm which has activated.

The alarm rearm time allows the user to set a time between sequential triggers of the same

alarm, and for how long the relays are set to their activated state. This can be set to 1, 5, 10 or

60 seconds.

5.9

Sony Set Menu

The Sony Set menu enables the user to adjust camera settings such as: white balance, gain,

sharpness, sync, backlight, and shutter. The Sony Set menu stores up to ten (10) Sony Set

tables, each containing ten (10) separate camera controls. A complete setup for the camera

module (shutter speed, gain level, effect, etc.) can be saved and reloaded via a user’s input,

as compared to having to modify each setting separately.

These can also be mapped to a MIC 500 Series Camera function, such as a preset number,

alarm input, or normal running, enabling the user to set up an ANPR mode or similar at a given

preset position, or set the camera to a fixed shutter speed when a given alarm goes off.

As soon as the camera moves from a position where a mode has been loaded, it loads the

Sony Set which is mapped to normal running, returning the camera to its standard state.

Additionally, there is an option to map to nothing; these can be called as and when required

using the learn preset command associated with the Sony Set table.

Note: Mapping a Sony Set table to a given function may cause a slight delay before the desired

function is carried out, depending on the number of actions stored in the table.

MANUAL CONTROL

Enables you to control the unit manually.

N/A

LEARN ALARM POS

Configure the tamper alarm or individual multialarm positions.

AUTO ALARM

POS OR 1 TO 12

RELAY 1 & 2 STATUS

See Section 5.8.1 Alarm Relays and Re-arm Time, page 35.

Normally Open/

Normally Closed

NORMALLY CLOSED

Disconnects the circuit when the relay is activated; the circuit is

connected when the relay is inactive.

N/A

NORMALLY OPEN

Connects the circuit when the relay is deactivated; the circuit is

connected when the relay is active.

N/A

(RELAY 1) SET WITH

ALARM

See Section 6.8.1 Alarm Relays and Re-arm Time, Page 41.

Inputs 1 - 4 / Any

Alarm

(RELAY 2) SET WITH

ALARM

See Section 6.8.1 Alarm Relays and Re-arm Time, Page 41.

Inputs 5 - 8 / Any

Alarm

Menu Item

Description

Options

Relay 1

Relay 2

Relay Activation Any Alarm Input

Alarm Inputs 1 - 4 Any Alarm Input Alarm Inputs 5 - 8

Relay State

Normally Open

Normally Closed

Normally Open

Normally Closed

MAIN MENU

2/2

SONY SET

SETUP

COMMANDS