Unofficial, Electronic fire commander (efc) wiring – Class1 Electronic Fire Commander User Manual

Page 6

background image

Unofficial

Electronic Fire Commander (EFC) Wiring

M

ATING

C

ONNECTOR

1:

DT06-4S

C

AVITY

C

IRCUIT

D

ESCRIPTION

DDC#

EFC I

NPUT

/O

UTPUT

A-1

DDEC Ignition Power

439

(+) System Power

A-2

DDEC Accessory Ground

953

(-) System Ground

A-3

DDEC #900 Data Link (+)

900

J1587 Serial Link

A-4

DDEC #901 Data Link (-)

901

J1587 Serial Link

M

ATING

C

ONNECTOR

2:

DT06-12S

C

AVITY

C

IRCUIT

D

ESCRIPTION

DDC#/PORT

EFC I

NPUT

/O

UTPUT

B-1

DDEC PGS Mode Select

523/H1

Output (ground) to DDEC

SIGNALS

DDEC

TO

TOGGLE

BETWEEN

PRESSURE

AND

RPM

MODE

B-2

OEM Interlock POS Input

-----

Input (+12 VDC) from OEM

PARKING

BRAKE

/

NEUTRAL

(

THROTTLE

READY

LED

)

B-3

cavity plug

-----

No Connection

B-4

DDEC PSG-PSI Mode Active

499/F3

Input (ground) from DDEC

GROUND

FROM

DDEC

WHEN

PSG

PRESSURE

MODE

IS

ACTIVE

(

PRESSURE

LED

LIGHTS

)

B-5

DDEC PSG Enable

543/G2

Output (ground) to DDEC

GROUND

TO

DDEC

TO

TURN

CRUISE

CONTROL

(

PSG

)

ON

(

CRUISE

ON

/

OFF

CONTROL

)

B-6

DDEC PSG Increase

545/G3

Output (ground) to DDEC

GROUND

TO

DDEC

TO

INCREASE

RPM

/

PRESSURE

(

RESUME

/

ACCEL

INCREASE

)

B-7

DDEC PSG Decrease

541/J1

Output (ground) to DDEC

GROUND

TO

DDEC

TO

DECREASE

RPM

/

PRESSURE

(

SET

/

COAST

DECREASE

)

B-8

DDEC Cruise Active

----Y3

Input (ground) from DDEC

GROUND

FROM

DDEC

TO

EFC

WHEN

CRUISE

CONTROL

(

PSG

)

SYSTEM

IS

ACTIVE

B-9

ALARM

-----

Output (ground) to Alarm

B-10

OK to PUMP Interlock POS Input

-----

Input (+12 VDC) from OEM

PTO

ENGAGED

/

PUMP

ENGAGED

B-11

cavity plug

-----

No Connection

B-12

Low Fuel

-----

Input (ground) from OEM

DDC circuit numbers and port assignments shown are typical but can differ from application to application.

MANUALS\EFC\

EFC

_

OPS

.

PM