Electronic Fire Commander (EFC) Wiring
M
ATING
C
ONNECTOR
1:
DT06-4S
C
AVITY
C
IRCUIT
D
ESCRIPTION
DDC#
EFC I
NPUT
/O
UTPUT
A-1
DDEC Ignition Power
439
(+) System Power
A-2
DDEC Accessory Ground
953
(-) System Ground
A-3
DDEC #900 Data Link (+)
900
J1587 Serial Link
A-4
DDEC #901 Data Link (-)
901
J1587 Serial Link
M
ATING
C
ONNECTOR
2:
DT06-12S
C
AVITY
C
IRCUIT
D
ESCRIPTION
DDC#/PORT
EFC I
NPUT
/O
UTPUT
B-1
DDEC PGS Mode Select
523/H1
Output (ground) to DDEC
SIGNALS
DDEC
TO
TOGGLE
BETWEEN
PRESSURE
AND
RPM
MODE
B-2
OEM Interlock POS Input
-----
Input (+12 VDC) from OEM
PARKING
BRAKE
/
NEUTRAL
(
THROTTLE
READY
LED
)
B-3
cavity plug
-----
No Connection
B-4
DDEC PSG-PSI Mode Active
499/F3
Input (ground) from DDEC
GROUND
FROM
DDEC
WHEN
PSG
PRESSURE
MODE
IS
ACTIVE
(
PRESSURE
LED
LIGHTS
)
B-5
DDEC PSG Enable
543/G2
Output (ground) to DDEC
GROUND
TO
DDEC
TO
TURN
CRUISE
CONTROL
(
PSG
)
ON
(
CRUISE
ON
/
OFF
CONTROL
)
B-6
DDEC PSG Increase
545/G3
Output (ground) to DDEC
GROUND
TO
DDEC
TO
INCREASE
RPM
/
PRESSURE
(
RESUME
/
ACCEL
INCREASE
)
B-7
DDEC PSG Decrease
541/J1
Output (ground) to DDEC
GROUND
TO
DDEC
TO
DECREASE
RPM
/
PRESSURE
(
SET
/
COAST
DECREASE
)
B-8
DDEC Cruise Active
----Y3
Input (ground) from DDEC
GROUND
FROM
DDEC
TO
EFC
WHEN
CRUISE
CONTROL
(
PSG
)
SYSTEM
IS
ACTIVE
B-9
ALARM
-----
Output (ground) to Alarm
B-10
OK to PUMP Interlock POS Input
-----
Input (+12 VDC) from OEM
PTO
ENGAGED
/
PUMP
ENGAGED
B-11
cavity plug
-----
No Connection
B-12
Low Fuel
-----
Input (ground) from OEM
DDC circuit numbers and port assignments shown are typical but can differ from application to application.
MANUALS\EFC\
EFC
_
OPS
.
PM
65..022798