beautypg.com

Page 6 of 6 pages – Class1 Digital Oxygen Remaining User Manual

Page 6

background image

page 6 of 6 pages

Engineering
Standards

Name

Identifier

Instructions

Engineering Standard Number

C1-102264-A

Digital Oxygen Remaining System

Red

Red

Black

12 VDC

Ground

Black

OEM Power Feed

manuals\digital\air_level\O2-wire.eps..100998

1
2
3
4

8
7
6
5

1

Alarm OUT (ground)

2

PSI IN (Pressure)

3

Sensor + 10 VDC

4

Power + 12 VDC

5

Ground

6

NC

7

NC

8

Alarm Silence (ground)

DTM06-08SA
0462-201-20141 20 Ga.

Wire Insertion View

Alarm OUT

PSI Signal
PSI Supply

Pressure Transducer

PIN

COLOR

1

PLUG

2

BLACK

3

RED

4

RED

5

BLACK

6

PLUG

7

PLUG

8

PLUG

PIN

COLOR

1

RED

2

BLACK

MANUALS\DIGITAL\AIR_LEFT\AM_HARN.AI

CONNECTOR

PROVIDED HARNESS

1.125"

1.425"

0.410"

RED

BLACK

Wiring Diagram for the Digital Oxygen Remaining Gauge.