J.p.instruments, Fuel flow installation manual, Specifications and limitations – J.P. Instruments EDM 760 Fuel Flow Installation Manual User Manual
Page 6
![background image](/manuals/546513/6/background.png)
J.P.Instruments
Fuel Flow Installation Manual
Report # 760
for EDM-760 temperature indicating system with Fuel Flow Option
Appendix - A
Page Page 6 of 14 Rev NC :
Date 07/20/99
7…
Specifications and Limitations
Model:
EDM- 760(), with Fuel Flow option
Case Dimensions:
2.5" x 2.5" x 7.5" depth, 3.125" Bezel.
Weight:
Unit Only:
16 oz
Flow Transducer:
3 oz
Environmental;
Passed TSO C43c and DO-178a (software level 3)
Power Requirements:
10 to 35 Volts, 2 Amp.
Low Fuel Warning Display
The display message will blink anytime the programmed Low Fuel Reminder, Low Fuel Warning or the Time
to Empty Limit are violated.
External Warning Control Line:
Grounds external light when any EDM-760 warning display is on or blinking. Current should be limited to
2/10 amp.
Accuracy:
Flow:
2% or better in accordance with TSO C44a.
Resolution
Fuel Flow:
0.1 Gal. or 1 Lb. or .1 Ltr.
Fuel Remaining:
0.1 Gal. or 1 Lb. or . 1 Ltr.
Fuel Used:
0.1 Gal. or 1 Lb. or .1 Ltr.
Time to Empty:
10 minute
Max Displayed Range (Unit Only):
Fuel Flow:
199.9 Gals. or 162.0 or Gal/Hr or 1199 Lbs/Hr or 749 Ltr/Hr.
Fuel Remaining:
999 Gals. or 811 or Gals. or 1999 Lbs. or 1999 Ltrs.
Fuel Used:
999 Gals. or 811 or Gals. or 1999 Lbs. or 1999 Ltrs.
Time to Empty:
19 hours 59 minutes