J.p.instruments, Fuel flow installation manual – J.P. Instruments EDM 760 Fuel Flow Installation Manual User Manual
Page 14
J.P.Instruments
Fuel Flow Installation Manual
Report # 760
for EDM-760 temperature indicating system with Fuel Flow Option
Appendix - A
Page Page 14 of 14 Rev NC :
Date 07/20/99
10.. Installing the Electronic International Fuel Flow Differential Module (FFDM-I):
If your engine is equipped with a fuel return line from the carburetor back to the fuel tank, install the
FFDM-1 in the aircraft as outlined below (see sheet one ). Otherwise, omit this step.
a) Connect the connector to the FFDM-I.
b) Install the FFDM-1 under the instrument panel using two tie wraps on each end of the module to
support it to a wire bundle or bracket.
c) Route and connect the 3' red power lead to the 12 or 24 volt bus via a 1 amp fuse.
d) Route and connect the 3' black ground lead to the same ground used for the EDM-760(),with Fuel
Flow option.
e) Route and connect the 6' red, black and white leads marked "Feed" to the flow transducer installed
in the fuel line from the fuel pump to the carburetor.
f) Route and connect the 6' red, black and white leads marked "Return" to the flow transducer
installed in the return fuel line from the carburetor to the fuel tank.
g) Connect the red, black and white leads to the same color 6' leads from the EDM-760(),with Fuel
Flow option.
Any excess wires can be rolled up and tie wrapped under the instrument panel. Tie wrap these wires
so they do not obstruct the freedom of travel of any controls.
J.P.INSTRUMENTS
PO Box 7033
Huntington Beach CA 92646
Title:
FFDM-1 Interconnect Wiring
Diagram
Drawing No.
700920
Date
02/14/97
Drawn
Approve
d
Sheet
2 of 2
Rev NC