J.p.instruments fuel flow installation manual, Fs-450, 14 list of major components – J.P. Instruments Fuel Scan 450 Installation Manual User Manual
Page 14: 15 instructions for continued airworthiness (ica)
![background image](/manuals/546498/14/background.png)
J.P.Instruments Fuel Flow Installation Manual
Report # 400
FS-450
Page 14 of 16
Rev A : Date 02/1/2002
14 List of Major components:
PN 450000-( )
-P
-G
-D
-H
-M
Indicator PN 450000
1
1
1
1
Indicator PN 450000-M
1
Harness PN 450507
1
1
1
Harness PN 450510
1
Harness PN 450506
1
Transducer PN 700900-1
1
2
2
Transducer PN 700900-2
1
Transducer High Flow PN FT4-8AEXS-LEA-2029
1
Part Number
Description
PN 450000-P
All pump fed Carburetor and injected engines with
maximum take-off flow range to 60 GPH
PN 450000-G
All Gravity feed systems without mechanical pump
PN 450000-D
All pressure carburetor systems with return line to tank
PN 450000-H
All mechanical pump fed systems with a high flow
range, on take-off, to 120 GPH.
PN 450000-M
Fuel flow for twin engine aircraft single indicator
15 Instructions for Continued Airworthiness (ICA)
There are no field adjustments and or calibration requirements for the P/N 450000 series instrument after initial
installation. ICA is not required. Maintenance of nonfunctioning or malfunctioning components is limited to
removal and replacement of JPI factory supplied new or repaired components as described in the
troubleshooting section of the installation instructions