SYSTEM CAPACITIES

SYSTEM

TYPE

NOMINAL

SYSTEM

CAPACITY

(Tons)

FAN COIL

TYPE(S)

INDOOR SECTIONS

OUTDOOR

SECTION

538

TOTAL

STANDARD

CFM (AT

HIGH

SPEED)

SYSTEM

NET

COOLING

(Btuh)

SYSTEM

NET

HEATING

(Btuh)*

SEER

HSPF*

OUTDOOR

SOUND

RATING

(Decibels)

Ckt

Qty

Model

No. 619

Cooling

Only

3

4

High Wall

1

E

009

A

009

286

8,500

10.5

65

1

1

E

012

A

012

358

11,800

11.0

65

1

1

2

1

E

018

C

018

534

17,300

11.5

70

2

1

E

024

C

024

521

22,600

12.0

68

Heat

Pump

3

4

High Wall

1

E

009

D

009

293

9,000

9,000

10.5

6.8

65

1

1

E

012

D

012

350

12,500

12,500

10.5

6.8

65

1

1

2

1

E

018

D

018

502

17,300

16,900

11.5

6.8

70

2

1

E

024

D

024

574

23,200

21,400

11.0

6.8

68

Multi-

Split

2

High Wall

A

2

E

018

S

024

1000

23,000

11.0

68

In-Ceiling Cassette

A

1

F

024

S

024

1059

23,000

11.0

68

High Wall

A

1

E

018

Ceiling Suspended

A

1

C

024†

S

024

1034

23,000

11.0

68

High Wall

A

1

E

018

4

High Wall

A

2

E

018

S

048

1068

46,000

11.0

72

B

2

E

018

High Wall

A

1

E

024

S

048

1589

46,000

11.0

72

B

2

E

018

High Wall

A

1

E

024

S

048

1042

46,000

11.0

72

B

1

E

024

High Wall

A

2

E

018

S

048

2102

46,000

11.0

72

High Wall

B

1

E

018

Ceiling-Suspended

B

1

C

024†

High Wall

A

2

E

018

S

048

2127

46,000

11.0

72

High Wall

B

1

E

018

In-Ceiling Cassette

B

1

F

024

High Wall

A

2

E

018

S

048

2068

47,000

11.0

72

Ceiling Suspended

B

2

C

024†

High Wall

A

2

E

018

S

048

2118

46,000

11.0

72

In-Ceiling Cassette

B

2

F

024

High Wall

A

2

E

018

S

048

2059

46,000

11.0

72

Ceiling Suspended

B

1

C

024†

In-Ceiling Cassette

B

1

F

024

Ceiling Suspended

A

2

C

024†

S

048

2034

47,000

11.0

72

Ceiling Suspended

B

1

C

024†

High Wall

B

1

E

018

Ceiling Suspended

A

2

C

024†

S

048

2059

47,000

11.0

72

In-Ceiling Cassette

B

1

F

024

High Wall

B

1

E

018

In-Ceiling Cassette

A

2

F

024

S

048

2109

46,000

11.0

72

In-Ceiling Cassette

B

1

F

024

High Wall

B

1

E

018

In-Ceiling Cassette

A

2

F

024

S

048

2084

46,000

11.0

72

Ceiling Suspended

B

1

C

024†

High Wall

B

1

E

018

High Wall

A

2

E

018

S

048

1983

47,000

11.0

72

In-Ceiling Cassette

B

1

F

036

High Wall

A

2

E

018

S

048

1668

45,800

11.0

72

Ceiling Suspended

B

1

C

024

High Wall

A

1

E

024

S

048

1521

46,800

11.0

72

In-Ceiling Cassette

B

1

F

036

High Wall

A

1

E

024

S

048

1559

45,800

11.0

72

Ceiling Suspended

B

1

C

024

Ceiling Suspended

A

2

C

024†

S

048

1436

46,800

11.0

72

High Wall

B

1

E

024

Ceiling Suspended

A

1

C

024†

S

048

1121

45,600

11.0

72

In-Ceiling Cassette

A

1

F

024

High Wall

B

1

E

024

LEGEND

Decibels — Sound Levels
Ckt

Circuit

HSPF

Heating Seasonal Performance Factors

SEER

Seasonal Energy Efficiency Ratio

*Heat pump systems only.

†Unit must be reconfigured for 1

1

2

ton (18,000 Btuh) operation. Refer to

installation instructions included with the fan coil unit for more details.

NOTES:
1. Rating condition is 80 F db, 67 F wb air entering indoor air section

and 95 F db air entering outdoor air section.

2. Total kW is for total system, including compressor and outdoor and

indoor fans.

3. Ratings are based on 25 ft of interconnecting refrigerant line.
4. All system ratings are based on fan coil units operating at high fan

speed. Consult Specifications tables for airflows at all available fan
speeds.