System capacities – Bryant High Wall Duct-Free Split System 619E User Manual
Page 5

SYSTEM CAPACITIES
SYSTEM
TYPE
NOMINAL
SYSTEM
CAPACITY
(Tons)
FAN COIL
TYPE(S)
INDOOR SECTIONS
OUTDOOR
SECTION
538
TOTAL
STANDARD
CFM (AT
HIGH
SPEED)
SYSTEM
NET
COOLING
(Btuh)
SYSTEM
NET
HEATING
(Btuh)*
SEER
HSPF*
OUTDOOR
SOUND
RATING
(Decibels)
Ckt
Qty
Model
No. 619
Cooling
Only
3
⁄
4
High Wall
—
1
E
009
A
009
286
8,500
—
10.5
—
65
1
—
1
E
012
A
012
358
11,800
—
11.0
—
65
1
1
⁄
2
—
1
E
018
C
018
534
17,300
—
11.5
—
70
2
—
1
E
024
C
024
521
22,600
—
12.0
—
68
Heat
Pump
3
⁄
4
High Wall
—
1
E
009
D
009
293
9,000
9,000
10.5
6.8
65
1
—
1
E
012
D
012
350
12,500
12,500
10.5
6.8
65
1
1
⁄
2
—
1
E
018
D
018
502
17,300
16,900
11.5
6.8
70
2
—
1
E
024
D
024
574
23,200
21,400
11.0
6.8
68
Multi-
Split
2
High Wall
A
2
E
018
S
024
1000
23,000
—
11.0
—
68
In-Ceiling Cassette
A
1
F
024
S
024
1059
23,000
—
11.0
—
68
High Wall
A
1
E
018
Ceiling Suspended
A
1
C
024†
S
024
1034
23,000
—
11.0
—
68
High Wall
A
1
E
018
4
High Wall
A
2
E
018
S
048
1068
46,000
—
11.0
—
72
B
2
E
018
High Wall
A
1
E
024
S
048
1589
46,000
—
11.0
—
72
B
2
E
018
High Wall
A
1
E
024
S
048
1042
46,000
—
11.0
—
72
B
1
E
024
High Wall
A
2
E
018
S
048
2102
46,000
—
11.0
—
72
High Wall
B
1
E
018
Ceiling-Suspended
B
1
C
024†
High Wall
A
2
E
018
S
048
2127
46,000
—
11.0
—
72
High Wall
B
1
E
018
In-Ceiling Cassette
B
1
F
024
High Wall
A
2
E
018
S
048
2068
47,000
—
11.0
—
72
Ceiling Suspended
B
2
C
024†
High Wall
A
2
E
018
S
048
2118
46,000
—
11.0
—
72
In-Ceiling Cassette
B
2
F
024
High Wall
A
2
E
018
S
048
2059
46,000
—
11.0
−
72
Ceiling Suspended
B
1
C
024†
In-Ceiling Cassette
B
1
F
024
Ceiling Suspended
A
2
C
024†
S
048
2034
47,000
—
11.0
—
72
Ceiling Suspended
B
1
C
024†
High Wall
B
1
E
018
Ceiling Suspended
A
2
C
024†
S
048
2059
47,000
—
11.0
—
72
In-Ceiling Cassette
B
1
F
024
High Wall
B
1
E
018
In-Ceiling Cassette
A
2
F
024
S
048
2109
46,000
—
11.0
—
72
In-Ceiling Cassette
B
1
F
024
High Wall
B
1
E
018
In-Ceiling Cassette
A
2
F
024
S
048
2084
46,000
—
11.0
—
72
Ceiling Suspended
B
1
C
024†
High Wall
B
1
E
018
High Wall
A
2
E
018
S
048
1983
47,000
—
11.0
—
72
In-Ceiling Cassette
B
1
F
036
High Wall
A
2
E
018
S
048
1668
45,800
—
11.0
—
72
Ceiling Suspended
B
1
C
024
High Wall
A
1
E
024
S
048
1521
46,800
−
11.0
—
72
In-Ceiling Cassette
B
1
F
036
High Wall
A
1
E
024
S
048
1559
45,800
—
11.0
—
72
Ceiling Suspended
B
1
C
024
Ceiling Suspended
A
2
C
024†
S
048
1436
46,800
—
11.0
−
72
High Wall
B
1
E
024
Ceiling Suspended
A
1
C
024†
S
048
1121
45,600
—
11.0
—
72
In-Ceiling Cassette
A
1
F
024
High Wall
B
1
E
024
LEGEND
Decibels — Sound Levels
Ckt
— Circuit
HSPF
— Heating Seasonal Performance Factors
SEER
— Seasonal Energy Efficiency Ratio
*Heat pump systems only.
†Unit must be reconfigured for 1
1
⁄
2
ton (18,000 Btuh) operation. Refer to
installation instructions included with the fan coil unit for more details.
NOTES:
1. Rating condition is 80 F db, 67 F wb air entering indoor air section
and 95 F db air entering outdoor air section.
2. Total kW is for total system, including compressor and outdoor and
indoor fans.
3. Ratings are based on 25 ft of interconnecting refrigerant line.
4. All system ratings are based on fan coil units operating at high fan
speed. Consult Specifications tables for airflows at all available fan
speeds.
5