Bryant High Wall Duct-Free Split System 619E User Manual
Page 10

DIMENSIONAL DRAWING — BASE UNIT — 538A018-024 CONDENSING UNITS
UNIT
538A
A
B
C
D
E
F
G
H
ft-in.
mm
ft-in.
mm
ft-in.
mm
ft-in.
mm
ft-in.
mm
ft-in.
mm
ft-in.
mm
ft-in.
mm
018
2-1
1
⁄
8
638.2 3-0
15
⁄
16
938.2 1-2
9
⁄
16
369.9
1-4
406.4 1-11
7
⁄
16
595.3 1-5
3
⁄
16
436.6 1-5
1
⁄
2
444.5 1-8
1
⁄
8
511.2
024
2-1
1
⁄
8
638.2 3-0
15
⁄
16
938.2 1-2
9
⁄
16
369.9
1-4
406.4 1-11
7
⁄
16
595.3 1-5
3
⁄
16
436.6 1-5
1
⁄
2
444.5 1-8
1
⁄
8
511.2
UNIT
538A
J
K
L
M
N
R
S
OPERATING
WT
ft-in.
mm
ft-in.
mm
ft-in.
mm
ft-in.
mm
ft-in. mm ft-in.
mm
ft-in.
mm
Lb
kg
018
1-1
1
⁄
4
336.6 0-6
5
⁄
8
168.3 0-10
13
⁄
16
274.6 0-0
5
⁄
8
15.00 0-0
3
⁄
8
9.52 0-4
1
⁄
2
115.0 0-6
1
⁄
2
166.0
150
68.0
024
1-2
7
⁄
16
366.7 0-6
3
⁄
4
171.4 1- 0
304.8 0-0
5
⁄
8
15.00 0-0
3
⁄
8
9.52 0-4
1
⁄
2
115.0 0-6
1
⁄
2
166.0
154
69.0
MINIMUM MOUNTING PAD DIMENSIONS
Support Feet
Snow Stand
Ice Stand
ft-in.
mm
ft-in.
mm
ft-in.
mm
1-11 x
3-6
584.2 x
1066.8
2-2 x
3-6
660.4 x
1066.8
2-2 x
3-6
660.4 x
1066.8
NOTES:
1. Required clearances, with coil facing wall, allow
6 in. minimum clearance on coil side and coil end,
and 3 ft minimum clearance on compressor end
and fan side. With fan facing wall, allow 8 in. mini-
mum clearance on fan side and coil end, and 3 ft
minimum clearance on compressor end and coil
side. With multi-unit application, arrange units so
discharge of one does not enter inlet of another.
2. Dimensions in parenthesis are in millimeters.
3.
Center of Gravity.
10