DIMENSIONAL DRAWING — BASE UNIT — 538A018-024 CONDENSING UNITS

UNIT
538A

A

B

C

D

E

F

G

H

ft-in.

mm

ft-in.

mm

ft-in.

mm

ft-in.

mm

ft-in.

mm

ft-in.

mm

ft-in.

mm

ft-in.

mm

018

2-1

1

8

638.2 3-0

15

16

938.2 1-2

9

16

369.9

1-4

406.4 1-11

7

16

595.3 1-5

3

16

436.6 1-5

1

2

444.5 1-8

1

8

511.2

024

2-1

1

8

638.2 3-0

15

16

938.2 1-2

9

16

369.9

1-4

406.4 1-11

7

16

595.3 1-5

3

16

436.6 1-5

1

2

444.5 1-8

1

8

511.2

UNIT
538A

J

K

L

M

N

R

S

OPERATING

WT

ft-in.

mm

ft-in.

mm

ft-in.

mm

ft-in.

mm

ft-in. mm ft-in.

mm

ft-in.

mm

Lb

kg

018

1-1

1

4

336.6 0-6

5

8

168.3 0-10

13

16

274.6 0-0

5

8

15.00 0-0

3

8

9.52 0-4

1

2

115.0 0-6

1

2

166.0

150

68.0

024

1-2

7

16

366.7 0-6

3

4

171.4 1- 0

304.8 0-0

5

8

15.00 0-0

3

8

9.52 0-4

1

2

115.0 0-6

1

2

166.0

154

69.0

MINIMUM MOUNTING PAD DIMENSIONS

Support Feet

Snow Stand

Ice Stand

ft-in.

mm

ft-in.

mm

ft-in.

mm

1-11 x

3-6

584.2 x

1066.8

2-2 x

3-6

660.4 x

1066.8

2-2 x

3-6

660.4 x

1066.8

NOTES:
1. Required clearances, with coil facing wall, allow

6 in. minimum clearance on coil side and coil end,
and 3 ft minimum clearance on compressor end
and fan side. With fan facing wall, allow 8 in. mini-
mum clearance on fan side and coil end, and 3 ft
minimum clearance on compressor end and coil
side. With multi-unit application, arrange units so
discharge of one does not enter inlet of another.

2. Dimensions in parenthesis are in millimeters.

3.

Center of Gravity.

10