beautypg.com

Safety chain, Hose assembly, Fig. 9 – L.B. White I-3 Infraconic User Manual

Page 11: Fig. 10, Fig. 7, Fig. 8, Fig. 11

background image

The safety chain hanging kit must be installed. Its purpose is
to provide a safety in the event the heater is accidentally
detached from its mounting on the crate panel. It also
provides a means to hang the heater out of the way during
room depopulation and cleaning.

1.

Connect key ring to toggle bolt, and safety latch and
chain to key ring. See Fig. 9.

2.

Drill a 5/8 in. diameter hole into the ceiling directly
above the heater and secure the toggle bolt with
hardware in place. See Fig.9

FIG. 9

3.

Connect opposite end of chain to key ring on heater
mounting frame. Take up any slack, and cut off excess
chain.

4

When cleaning the room or depopulating, detach the
heater’s safety pin and connect the heater’s key ring to
the snap latch at the toggle bolt. See Fig.10

FIG. 10

.

FIG. 7

b.. Locate the heater with mount to the planned position on

the crate panel. Push the assembly firmly onto the panel.

c.

Using the lower base holes as templates, drill 5/16 in.
holes through the divider panel , both sides. See Fig.8.
Secure the base mount to the panel with nuts and bolts
i n c l u d e d . P r o c e e d t o S a f e t y C h a i n I n s t a l l a t i o n
Instructions.

FIG. 8

Safety Chain

(part 26771)

10

LOWER HOLES
INSTALL NUTS AND BOLTS BOTH
ENDS

HOSE ASSEMBLY

TO GAS SUPPLY

MANUAL SHUT-OFF

BUSHING

HOSE 1/4" RIGID X SWIVEL
W/ EXCESS FLOW VALVE

TO GAS SUPPLY

MANUAL SHUT-OFF

HOSE 1/4" Q.C. X SWIVEL NUT

MALE QUICK CONNECT

FEMALE QUICK CONNECT

W/ EXCESS FLOW VALVE

COLLAR

MALE END

A

-- PULL BACK COUPLING COLLAR

TO REMOVE DUST CAP.

-- REMOVE DUST CAP FROM
MALE END OF HOSE.
-- FIRMLY PUSH MALE HOSE END
INTO COUPLING.
-- RELEASE COLLAR.

ENSURE MALE HOSE END IS

SECURELY LOCKED INTO COUPLING

TO GAS INLET AT HEATER

FIG. 11

.