6 testing & final assembly, Testing the air locker actuation, Re-sealing & filling the differential – ARB RD166 User Manual
Page 39
6 Testing & Final Assembly
37
6.3
Testing the Air Locker Actuation
To test that your air system, electrical system, and your Air Locker
differential is functioning correctly:
F
Support the vehicle such that the wheels are free to rotate (e.g., on
axle stands, a chassis hoist, etc.)
F
Leave the parking brake off, the transmission in neutral, and the Air
Locker VZLWFKµ2))¶
F
7XUQWKHLJQLWLRQWRWKHµ21¶SRVLWLRQOHDYLQJWKHPRWRURII7KH
large illuminating symbol on the Air Locker switch cover should be
µ2))¶
F
Turn the compressor (or alternate air source) on to charge the air
supply up to its maximum pressure.
F
While supporting the drive shaft flange, rotate one wheel by hand.
F
The wheel should rotate freely and the opposite wheel should be
turning in the opposite direction without any resistance or
mechanical noise from within the differential.
F
Turn the Air Locker VZLWFKWRWKHµ21¶SRVLWLRQ7KHLOOXPLQDWHG
symbol on the switch cover should light up.
F
Rotate the same wheel again.
F
Both wheels should rotate together.
F
Turn the switch off again.
F
Rotate the same wheel.
F
The wheels should again rotate in opposite directions.
6.4
Re-Sealing & Filling the Differential
NOTE : Consult the ARB Air Locker Operating & Service
Manual for recommendations on differential lubricant
specifications.
F
Replace the differential cover using gasket sealant or a new
standard differential cover gasket for your make of vehicle.
F
Refill the differential until level with the filler hole.
F
Rotate the differential center 2 full turns.
F
Check the oil level and add oil if necessary.
F
Replace filler plug (apply thread sealant to filler plug before
inserting if it is a threaded type plug).
F
Wipe differential housing clean of any oil or grease which may
collect dirt or other abrasive particles.