PROBLEM
POSSIBLE CAUSE
CORRECTION
Hitch will not raise
Low oil level.
Loose electrical connections.
Blown fuse.
Check and fill hydraulic reservoir.
Check connections at
electrohydraulic valve and
controls.
Replace fuse.
Hitch raises too slowly or
quickly
Rate of raise adjustment
incorrectly set.
Adjust flow control on 3-point
hitch valve section.
Hitch drops too slowly or
quickly
Lowering rate adjustment
incorrectly set.
Adjust rate of lowering flow
control knob.
Hitch overstrokes during
raise or lower and puts the
pump into high pressure
standby
Feedback potentiometer
incorrectly adjusted.
Adjust potentiometer.
BRAKES
PROBLEM
POSSIBLE CAUSE
CORRECTION
Park brake inoperative
Worn brake pads.
Broken park brake cable.
Brake out of adjustment.
Replace brake pads.
Replace broken cable.
Operate park brake lever several
times to automatically adjust
brakes. If no result, contact your
Buhler Versatile dealer.
Pedal bottoms out or feels
mushy
Brake piston seal leaking.
Worn brake pads.
Brake bleeder not sealing.
Leakage in brake valve.
Air in system.
Reservoir level low.
Brakes out of adjustment.
Contact Buhler Versatile dealer.
Replace brake pads.
Tighten bleeder.
Contact Buhler Versatile dealer.
Bleed brake system.
Fill reservoir with proper brake
fluid.
Operate park brake lever several
times to automatically adjust. If no
result, contact Buhler Versatile
dealer.