Tractor performance monitor (optional) – Buhler 2425 User Manual
Page 159

SECTION 2 - OPERATION
2-101
TRACTOR PERFORMANCE MONITOR (Optional)
DESCRIPTION AND OPERATION
The optional Tractor Performance Monitor
automatically begins to work as the ignition
switch is turned to the “RUN” position.
The system consists of the following items:
Control Console - LCD display and three
touch-sensitive switches.
Radar Ground Speed Sensor- Determines
true ground speed.
Implement Status Switch - Determines
whether implement is engaged.
Transmission Output Shaft Sensor - Actual
wheel speed.
The system provides operating information on:
Area/Hour - Acres (or Hectares) per hour based
on last five seconds of operation.
Area - Total accumulated area (since the last
reset of AREA display).
Slip - Wheel slip in percent (%) with alarm.
Each function readout can be displayed by
touching the respective switch (except alarms)
at any time.