beautypg.com

Installing your cooker – Glen Dimplex Home Appliances Ltd 100 User Manual

Page 25

background image

Installing Your Cooker

The information below is crucial to installing this appliance

correctly and safely.

Where standards have been revised - always use the most

recent edition.

Failure to install appliances correctly is dangerous

and could lead to prosecution.

Ventilation Requirements

The room containing the appliance should have an air

supply in accordance with BS 5440:Part 2.

All rooms require an openable window, or equivalent,

and some will require a permanent vent as well.

For room volumes up to 5m✓ an air vent of 100cm✓ is

required.

If the room has a door which opens directly to the
outside, or exceeds 10m✓ - no air vent is required.

For room volumes between 5m✓ and 10m✓ and air vent
of 50cm✒ is required.

If there are other fuel burning appliances in the same

room, BS 5440:Part 2 should be consulted to determine

the air vent requirements.

This appliance must not be fitted into a bed sitting room
of less than 20m✓ or into a bath or shower room.

Windows and vents should not be blocked or removed

without first consulting a competent engineer.

LPG only - do not install this appliance below ground

level. This does not preclude installation into rooms which

are basements with respect to one side of the building, but

open to ground level on the opposite side

.