Rev. 2.01 – BIXOLON 352plusA User Manual
Page 11
Rev. 2.01
- 11 -
SRP-350/352plusA&C
2-2-3 Setting the DIP switch (IEEE1284 Parallel, USB Interface)
• DIP Switch 1
SW
Function
ON
OFF
Default
1-1
Auto Line Feed
Enable
Disable
OFF
1-2
~
1-8
Reserved -
-
OFF
• DIP Switch 2
SW
Function
ON
OFF
Default
2-1 Reserved
-
-
OFF
2-2
Internal bell control
Internal bell disable
Internal bell enable
OFF
2-3 Auto
Cutter
Disable
Enable
OFF
2-4
BUSY Condition
Receive Buffer Full
* Offline
* Receive Buffer Full
OFF
2-5
OFF
2-6
OFF
2-7
Print Density
Refer to the following Table 2
OFF
2-8
Near-End Sensor Status
Disable
Enable
OFF
• Table 1 – Baud rate (bps) Selection
Transmission Speed
1-6
1-7
1-8
Default
2400 ON
OFF
OFF
4800 ON
OFF
ON
9600 OFF
ON
OFF
19200
OFF OFF OFF
38400 OFF
ON
ON
57600 OFF
OFF
ON
115200
ON ON ON
9600
• Table 2 – Print Density Selection
2-5
2-6
2-7
Print Density (Mono color)
Default
ON ON
Reserved
1(Light)
OFF OFF
Reserved
2
ON OFF
Reserved
3
OFF ON
Reserved
4(Dark)
2
2-5
2-6
2-7
Print Density (Two colors )
Default
ON ON ON
80%
ON ON OFF
90%
OFF OFF ON
95%
OFF OFF OFF
100%
ON OFF ON
105%
ON OFF OFF
110%
OFF ON ON
120%
OFF ON OFF
130%
100%
※
Auto Cutter Enable / Disable selection
Dip Switch Set 2
ON
Auto Cutter Disabled
SW 2-3
OFF
Auto Cutter Enabled
Application