beautypg.com

Bryant 340AAV User Manual

Page 9

background image

—9—

COMBUSTION-AIR AND VENT PIPING Direct-Vent/2-Pipe (All Sizes) and

Non-Direct Vent/1-Pipe (Sizes 040 Through 120 Only) Applications

MAXIMUM ALLOWABLE PIPE LENGTH (FT) (CONTINUED)

ALTITUDE (FT)

UNIT SIZE

(BTUH)

DIRECT VENT (2-PIPE) ONLY

NON-DIRECT VENT

(1-PIPE) ONLY

NUMBER OF 90° ELBOWS

TERMINATION

TYPE

PIPE DIA

(IN.)*

PIPE DIA

(IN.)*

1

2

3

4

5

6

4001 to 5000‡

40,000

2 Pipe or 2-in

Concentric

1-1/2

1-1/2

60

55

50

45

44

39

2

2

70

70

70

70

70

70

60,000

2 Pipe or 2-in

Concentric

1-1/2

1-1/2

15

10

5

NA

NA

NA

2

2

64

59

58

53

52

52

80,000

2 Pipe or 2-in

Concentric

2

2

44

39

26

21

20

11

2-1/2

2-1/2

70

70

70

70

70

70

100,000

2 Pipe or 3-in

Concentric

2-1/2

2-1/2

31

22

13

12

NA

NA

3

3

70

70

67

62

57

52

120,000

2 Pipe or 3-in.

Concentric

3† no disk

NA

53

46

40

33

26

20

NA

3†

56

55

54

53

52

52

4† no disk

4† no disk

70

70

70

70

70

70

140,000

2 Pipe or 3-in.

Concentric

3† no disk

NA

21

17

13

9

5

NA

4† no disk

NA

69

64

59

54

49

44

ALTITUDE (FT)

UNIT SIZE

(BTUH)

DIRECT VENT (2-PIPE) ONLY

NON-DIRECT VENT

(1-PIPE) ONLY

NUMBER OF 90° ELBOWS

TERMINATION

TYPE

PIPE DIA

(IN.)*

PIPE DIA

(IN.)*

1

2

3

4

5

6

5001 to 6000‡

40,000

2 Pipe or 2-in

Concentric

1-1/2

1-1/2

57

52

47

42

40

35

2

2

70

70

70

70

70

70

60,000

2 Pipe or 2-in

Concentric

1-1/2

1-1/2

14

9

NA

NA

NA

NA

2

2

60

55

54

49

48

47

80,000

2 Pipe or 2-in

Concentric

2

2

41

36

23

18

17

8

2-1/2

2-1/2

70

70

70

70

70

70

100,000

2 Pipe or 3-in

Concentric

2-1/2

2-1/2

29

21

12

11

NA

NA

3

3

70

67

62

57

52

47

120,000

2 Pipe or 3-in.

Concentric

3† no disk

NA

42

35

29

22

15

9

NA

3†

53

52

50

49

48

47

4† no disk

4† no disk

70

70

70

70

70

70

140,000

2 Pipe or 3-in.

Concentric

3† no disk

NA

12

8

NA

NA

NA

NA

4† no disk

NA

42

37

32

27

22

17

ALTITUDE (FT)

UNIT SIZE

(BTUH)

DIRECT VENT (2-PIPE) ONLY

NON-DIRECT VENT

(1-PIPE) ONLY

NUMBER OF 90° ELBOWS

TERMINATION

TYPE

PIPE DIA

(IN)*

PIPE DIA

(IN)*

1

2

3

4

5

6

6001 to 7000‡

40,000

2 Pipe or 2-in

Concentric

1-1/2

1-1/2

53

48

43

38

37

32

2

2

70

70

68

67

66

64

60,000

2 Pipe or 2-in

Concentric

1-1/2

1-1/2

13

8

NA

NA

NA

NA

2

2

57

52

50

45

44

43

80,000

2 Pipe or 2-in

Concentric

2

2

38

33

21

16

15

6

2-1/2

2-1/2

70

70

68

67

66

64

100,000

2 Pipe or 3-in

Concentric

2-1/2

2-1/2

27

19

10

9

NA

NA

3

3

68

63

58

53

48

43

120,000

2 Pipe or 3-in.

Concentric

3† no disk

NA

31

24

18

11

NA

NA

NA

3†

49

48

47

45

44

43

4† no disk

4† no disk

70

70

70

70

67

62

140,000

2 Pipe or 3-in.

Concentric

4† no disk

NA

17

12

7

NA

NA

NA

See notes at end of table