6— specifications – Bryant 340AAV User Manual

Page 6

background image

—6—

SPECIFICATIONS

See notes on page 7.

UNIT SIZE

048080

060080

048100

060100

060120

060140

RATINGS AND PERFORMANCE

Input Btuh*

80,000

80,000

100,000

100,000

120,000

140,000

Output Capacity
BTUH* (ICS)
(Shaded capacities
are specified on rat-
ing plate)

Direct Vent (2-Pipe)

Upflow

74,000

74,000

93,000

93,000

112,000

127,000

Downflow

74,000

74,000

93,000

93,000

112,000

127,000

Horizontal

74,000

74,000

93,000

93,000

112,000

127,000

Non-Direct Vent (1-Pipe)

Upflow

74,000

74,000

93,000

93,000

112,000

NA

Downflow

74,000

74,000

93,000

93,000

112,000

NA

Horizontal

74,000

74,000

93,000

93,000

112,000

NA

AFUE%

Nonweatherized ICS

Direct Vent (2-Pipe)

Upflow

92.3

92.3

92.3

92.3

92.3

92.3

Downflow

91.2

91.2

91.2

91.2

91.2

91.2

Horizontal

92.1

92.1

92.1

92.1

92.1

92

Non-Direct Vent (1-Pipe)

Upflow

92.1

NA

Downflow

91

NA

Horizontal

91

NA

Certified Temperature Rise Range °F

30—60

15—45

45—75

30—60

20—50

40—70

Certified External Static Pressure

Heating

0.10

0.10

0.12

0.12

0.12

0.15

Cooling

0.50

0.50

0.50

0.50

0.50

0.50

Airflow CFM‡

Heating

850

1125

885

1065

1320

1190

Cooling

895

1215

900

1200

1545

1245

ELECTRICAL

Unit Volts—Hertz—Phase

115—60—1

Operating Voltage Range Min—Max**

104—127

Maximum Unit Amps

6.1

7.3

6.1

7.1

9.5

7.6

Unit Ampacity††

8.4

10.0

8.4

9.8

12.8

10.4

Minimum Wire Size

14

14

14

14

14

14

Maximum Wire Length (Ft)‡‡

44

37

44

38

29

36

Maximum Fuse Size or Ckt Bkr Amps

(Time-Delay Type Recommended)

15

15

15

15

15

15

Transformer (24v)

40va

External Control

Heating

12va

Power Available

Cooling

21va

Air Conditioning Blower Relay

Standard

CONTROLS

Limit Control

SPST

Heating Blower Control (Off Delay)

Factory-Set at 135 Sec

Burners (Monoport)

2

2

3

3

3

4

Gas Connection Size

1/2-in. NPT

GAS CONTROLS

Gas Valve (Redundant)

Manufacturer

White-Rodgers

Min Inlet Pressure (In. wc)

4.5 (Natural Gas)

Max Inlet Pressure (In. wc)

13.6 (Natural Gas)

Ignition Device

Hot Surface

BLOWER DATA

Direct-Drive Motor HP (Permanent Split Capacitor)

1/5

1/3

1/5

1/3

1/2

1/3

Motor Full Load Amps

4.9

5.8

4.9

5.8

7.9

5.8

RPM (Nominal)—Speeds

1075—3

1075—4

1075—3

1075—4

Blower Wheel Diameter x Width (In.)

10 x 6

10 x 7

10 x 6

10 x 7

11 x 8

10 x 7

Filter Size (In.)—Permanent Washable

(1) 16 x 25 x 1

FACTORY-AUTHORIZED AND LISTED, DEALER-INSTALLED OPTIONS

Gas Conversion Kit—Natural-to-Propane

KGANP4001ALL

Gas Conversion Kit—Propane-to-Natural

KGAPN3301ALL

Twinning Kit

N/A

KGATW0601HSI

N/A

Manufactured (Mobile) Home Kit

KGAMH0101KIT

Downflow Base***

KGASB0201ALL

Vent Termination Kit (Bracket Only for 2 Pipes)

2-in.—KGAVT0101BRA

3-in.—KGAVT0201BRA

Concentric Vent Termination Kit (Single Exit)

2-in.—KGAVT0501CVT

3-in.—KGAVT0601CVT

Condensate Freeze Protection Kit

KGAHT0101CFP

Condensate Neutralizer Kit (Obtained Thru RCD)

P908-0001

Side Filter Rack (Without Filter)—Upflow ONLY

KGAFR0206ALL

Electronic/Mechanical Air Cleaner

Model EACB, EZXCAB, or FILCAB

Humidifier

Model HUM

Heat/Energy Recovery Ventilator

Model HRV

UV Lights

Model UVL

Door Gasket Kit

KGBAC0110DGK