—2—

DIMENSIONS (In.)

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (In.)

* Floor may be combustible.

NOTE:

Adequate service clearance should be provided over and above these dimensions as required.

UNIT

SIZE

UNIT DIMENSIONS

FLUE

HEIGHT

RETURN

OPENING

SUPPLY

OPENING

VENT

CONN

Width

Depth

Height

A

B

C

D

E

036105

21-1/4

53-3/4

31-1/2

26-1/2

20

20

5

060120

21-1/4

60-5/32

34-3/4

28-11/32

22

24

6

UNIT APPLICATION

LOW-BOY

SIDES

Furnace

1

Supply Plenum and Warm-Air Duct Within 6 ft of Furnace

1

BACK

Service Clearance

19

TOP

Furnace Casing or Plenum

2

Horizontal Warm-Air Duct Within 6 ft of Furnace

2

BOTTOM*

0

FLUE PIPE

Horizontally or Below Pipe

4

Vertically Above Pipe

9

FRONT

8

A98009

ama

A

D

10"

E

3"

B

C

21

1

4

20"

20"

20"

VENT
CONN