Trained service technician’s regular maintenance – Beckett FII 85 User Manual
Page 13
RWB 6104 BAFII R01
Page 13
Stop
Screw
AFII 85
AFII 100
AFII 150
0
0.40-0.65
0.5-0.65
0.75-1.00
1
-
0.6-0.75
0.85-1.10
2
-
0.65-0.80
0.95-1.15
3
0.60-0.75
0.65-0.90
0.95-1.20
4
-
0.75-0.95
1.10-1.25
5
0.70-0.85
0.85-1.00
1.15-1.35
6
-
0.95-1.10
1.15-1.40
7
-
-
1.25-1.50
8
-
-
1.30-1.50
HLX Firing Rate
Firing Rate
@ 140 psig
AFII 85
AFII 100
AFII 150
0.40-0.65
3
-
-
0.60-0.75
4
3
-
0.70-0.85
5
4
-
0.75-1.00
-
5
2
0.95-1.20
-
-
3
1.15-1.35
-
-
4
1.25-1.50
-
-
5
HLX Air Dial Setting
Trained Service Technician’s Regular Maintenance
Head
AFII 85
AFII 100
AFII 150
FB0
0.40-0.65
0.55-0.75 0.75-1.00
FB3
0.55-0.85
0.55-1.10 0.85-1.20
FB4
-
0.75-1.10 1.10-1.25
FB6
-
0.85-1.15 1.15-1.35
FBX Firing Rate
Firing Rate @
140 psig
AFII 85
AFII 100
AFII 150
0.40-0.65
3
-
-
0.60-0.75
4
3
-
0.70-0.85
5
4
-
0.75-1.00
-
5
2
0.95-1.20
-
-
3
1.15-1.35
-
-
4
1.25-1.50
-
-
5
FBX Air Dial Setting