Changing the bulb, Warning, Caution – Bosch B24IF User Manual
Page 25: Halogen bulbs above
25
Fault
Remedial action
Possible cause
Ice is forming in the supply hose to
the ice maker.
The water pressure is too low.
Check water pressure. The water pressure must be
between 25 and 120 p.s.i. (1.72ć8.25 bar).
The freezer compartment temperature
is too low.
Check temperature of the freezer compartment.
If required increase the temperature.
Water is flowing out of the
appliance.
The water pipe in the appliance is
defective.
Call customer service immediately.
pp
è Close shutĆoff valve immediately.
The water pressure is too low.
The valve may leak if the water pressure is too low.
The water pressure must be between 25 and 120 p.s.i.
(1.72ć8.25 bar).
A wrong water valve has been
installed.
SelfĆtapping valves and 3/16 inch (4.76 mm) saddle
valves reduce the water pressure and may eventually
block the pipe.
The manufacturer is not liable for damage to
property due to an incorrect installation or water
connection.
Changing the
bulb
d
WARNING
d
To avoid electrical shock which
can cause severe personal injury
or death, disconnect power to
appliance before making repairs.
After making repairs, reconnect
power.
q Switch off the appliance with
the POWER button!
CAUTION
Never touch a halogen bulb with
bare fingers. When inserting
a glass halogen bulb, always hold
with a soft cloth.
We recommend that a service
technician changes the bulb.
Halogen bulbs above
Halogen bulb type:
20 W/12 V/bulb holder G4
q Release and remove the cover.
q Pull out the defective halogen
bulb.
q Insert a new halogen bulb.
Touch the halogen bulb with
a soft cloth only.
q Attach the cover to the clip and
lock into position.