Troubleshooting
Freezer
Fault
Possible cause
Remedial action
Appliance has no cooling capacity.
The interior light does not function.
The display does not come on.
Power failure; the fuse has actuated;
the plug has not been inserted in the
electrical outlet properly.
Check that the power is on.
The fuse must be switched on.
Check the plug.
The refrigerating unit switches on
f
f
Appliance door opened frequently.
Do not open the door unnecessarily.
g
g
more and more frequently and for
longer.
Large quantities of fresh food placed in
the appliance.
Switch on Super function.
The ventilation openings are covered.
Remove obstacles and dirt.
The temperature in the freezer
compartment is too cold.
Temperature has been set too low.
Set a warmer temperature (see Setting the
temperature").
The interior light does not function.
The bulb is defective.
Change the bulb (see Changing the bulb").
The light switch is sticking.
Check whether it can be moved.
The appliance is giving off odors.
StrongĆsmelling foods have not been
packed in airtight containers.
Clean the appliance. Pack strongĆsmelling foods in
airtight containers (see Odors").
Dispenser/IceMaker
Fault
Possible cause
Remedial action
Request of water is impossible, but
dispensing of ice does function.
Appliance failure.
Call customer service immediately.
Ice maker and/or dispenser does not
appear to be running.
The ice maker is not connected to the
power supply.
Call customer service.
pp
g
The childproof lock of dispenser is
activated.
Switch off the childproof lock.
The ice maker has no water supply.
Ensure that the water supply line is connected properly.
If the water connection is accurat, call customer service.
The freezer compartment temperature
is too high.
Check temperature of the freezer compartment.
If required, lower the temperature.
Small ice cubes over a prolonged
period.
Other domestic appliances which use
water are in operation.
Avoid using e.g. a dishwasher, washing machine or
shower at the same time.
p
Water filter must be changed.
Instructions for changing the water filter can be found in
the section Water filter".
Wrong water pressure.
Check water pressure. The water pressure must be
between 25 and 120 p.s.i. (1.72ć8.25 bar).
A wrong water valve has been
installed.
SelfĆtapping valves and 3/16 inch (4.76 mm) saddle
valves reduce the water pressure and may eventually
block the pipe.
The manufacturer is not liable for damage to
property due to an incorrect installation or water